10 C.F.R. § 36.37   Power failures.


Title 10 - Energy


Title 10: Energy
PART 36—LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS
Subpart C—Design and Performance Requirements for Irradiators

Browse Previous |  Browse Next

§ 36.37   Power failures.

(a) If electrical power at a panoramic irradiator is lost for longer than 10 seconds, the sources must automatically return to the shielded position.

(b) The lock on the door of the radiation room of a panoramic irradiator may not be deactivated by a power failure.

(c) During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.

Browse Previous |  Browse Next