14 C.F.R. § 27.971 Fuel tank sump.
Title 14 - Aeronautics and Space
(a) Each fuel tank must have a drainable sump with an effective capacity in any ground attitude to be expected in service of 0.25 percent of the tank capacity or 1/16 gallon, whichever is greater, unless— (1) The fuel system has a sediment bowl or chamber that is accessible for preflight drainage and has a minimum capacity of 1 ounce for every 20 gallons of fuel tank capacity; and (2) Each fuel tank drain is located so that in any ground attitude to be expected in service, water will drain from all parts of the tank to the sediment bowl or chamber. (b) Each sump, sediment bowl, and sediment chamber drain required by this section must comply with the drain provisions of §27.999(b). [Amdt. 27–23, 53 FR 34213, Sept. 2, 1988]
Title 14: Aeronautics and Space
PART 27—AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT
Subpart E—Powerplant
Fuel System
§ 27.971 Fuel tank sump.