14 C.F.R. § 125.157 Lines and fittings.
Title 14 - Aeronautics and Space
(a) Each line, and its fittings, that is located in a designated fire zone, if it carries flammable fluids or gases under pressure, or is attached directly to the engine, or is subject to relative motion between components (except lines and fittings forming an integral part of the engine), must be flexible and fire-resistant with fire-resistant, factory-fixed, detachable, or other approved fire-resistant ends. (b) Lines and fittings that are not subject to pressure or to relative motion between components must be of fire-resistant materials.
Title 14: Aeronautics and Space
PART 125—CERTIFICATION AND OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD CAPACITY OF 6,000 POUNDS OR MORE; AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT
Subpart E—Special Airworthiness Requirements
§ 125.157 Lines and fittings.