16 C.F.R. § 1615.3 General requirements.
Title 16 - Commercial Practices
(a) Summary of test method. Five conditioned specimens, 8.9 × 25.4 cm. (3.5 × 10 in.), are suspended one at a time vertically in holders in a prescribed cabinet and subjected to a standard flame along their bottom edge for a specified time under controlled conditions. The char length is measured. (b) Test criteria. The test criteria when the testing is done in accordance with §1615.4 Test procedure are: (1) Average char length. The average char length of five specimens shall not exceed 17.8 cm. (7.0 in.). (2) Full specimen burn. No individual specimen shall have a char length of 25.4 cm. (10 in.). [40 FR 59903, Dec. 30, 1975, as amended at 43 FR 4853, Feb. 6, 1978]
Title 16: Commercial Practices
PART 1615—STANDARD FOR THE FLAMMABILITY OF CHILDREN'S SLEEPWEAR: SIZES 0 THROUGH 6X (FF 3–71)
Subpart A—The Standard
§ 1615.3 General requirements.