21 C.F.R. PART 868—ANESTHESIOLOGY DEVICES
Title 21 - Food and Drugs
Authority: 21 U.S.C. 351, 360, 360c, 360e, 360j, 371.
Source: 47 FR 31142, July 16, 1982, unless otherwise noted.
(a) This part sets forth the classification of anesthesiology devices intended for human use that are in commercial distribution. (b) The identification of a device in a regulation in this part is not a precise description of every device that is, or will be, subject to the regulation. A manufacturer who submits a premarket notification submission for a device under part 807 may not show merely that the device is accurately described by the section title and identification provisions of a regulation in this part, but shall state why the device is substantially equivalent to other devices, as required by §807.87. (c) To avoid duplicative listings, an anesthesiology device that has two or more types of uses (e.g., used both as a diagnostic device and as a therapeutic device) is listed only in one subpart. (d) References in this part to regulatory sections of the Code of Federal Regulations are to chapter I of title 21, unless otherwise noted. (e) Guidance documents referenced in this part are available on the Internet at http://www.fda.gov/cdrh/guidance.php. [52 FR 17734, May 11, 1987, as amended at 67 FR 76681, Dec. 13, 2002] A device included in this part that is classified into class III (premarket approval) shall not be commercially distributed after the date shown in the regulation classifying the device unless the manufacturer has an approval under section 515 of the act (unless an exemption has been granted under section 520(g)(2) of the act). An approval under section 515 of the act consists of FDA's issuance of an order approving an application for premarket approval (PMA) for the device or declaring completed a product development protocol (PDP) for the device. (a) Before FDA requires that a device commercially distributed before the enactment date of the amendments, or a device that has been found substantially equivalent to such a device, has an approval under section 515 of the act FDA must promulgate a regulation under section 515(b) of the act requiring such approval, except as provided in paragraph (b) of this section. Such a regulation under section 515(b) of the act shall not be effective during the grace period ending on the 90th day after its promulgation or on the last day of the 30th full calendar month after the regulation that classifies the device into class III is effective, whichever is later. See section 501(f)(2)(B) of the act. Accordingly, unless an effective date of the requirement for premarket approval is shown in the regulation for a device classified into class III in this part, the device may be commercially distributed without FDA's issuance of an order approving a PMA or declaring completed a PDP for the device. If FDA promulgates a regulation under section 515(b) of the act requiring premarket approval for a device, section 501(f)(1)(A) of the act applies to the device. (b) Any new, not substantially equivalent, device introduced into commercial distribution on or after May 28, 1976, including a device formerly marketed that has been substantially altered, is classified by statute (section 513(f) of the act) into class III without any grace period and FDA must have issued an order approving a PMA or declaring completed a PDP for the device before the device is commercially distributed unless it is reclassified. If FDA knows that a device being commercially distributed may be a “new” device as defined in this section because of any new intended use or other reasons, FDA may codify the statutory classification of the device into class III for such new use. Accordingly, the regulation for such a class III device states that as of the enactment date of the amendments, May 28, 1976, the device must have an approval under section 515 of the act before commercial distribution. [52 FR 17734, May 11, 1987] The exemption from the requirement of premarket notification (section 510(k) of the act) for a generic type of class I or II device is only to the extent that the device has existing or reasonably foreseeable characteristics of commercially distributed devices within that generic type or, in the case of in vitro diagnostic devices, only to the extent that misdiagnosis as a result of using the device would not be associated with high morbidity or mortality. Accordingly, manufacturers of any commercially distributed class I or II device for which FDA has granted an exemption from the requirement of premarket notification must still submit a premarket notification to FDA before introducing or delivering for introduction into interstate commerce for commercial distribution the device when: (a) The device is intended for a use different from the intended use of a legally marketed device in that generic type of device; e.g., the device is intended for a different medical purpose, or the device is intended for lay use where the former intended use was by health care professionals only; (b) The modified device operates using a different fundamental scientific technology than a legally marketed device in that generic type of device; e.g., a surgical instrument cuts tissue with a laser beam rather than with a sharpened metal blade, or an in vitro diagnostic device detects or identifies infectious agents by using deoxyribonucleic acid (DNA) probe or nucleic acid hybridization technology rather than culture or immunoassay technology; or (c) The device is an in vitro device that is intended: (1) For use in the diagnosis, monitoring, or screening of neoplastic diseases with the exception of immunohistochemical devices; (2) For use in screening or diagnosis of familial or acquired genetic disorders, including inborn errors of metabolism; (3) For measuring an analyte that serves as a surrogate marker for screening, diagnosis, or monitoring life-threatening diseases such as acquired immune deficiency syndrome (AIDS), chronic or active hepatitis, tuberculosis, or myocardial infarction or to monitor therapy; (4) For assessing the risk of cardiovascular diseases; (5) For use in diabetes management; (6) For identifying or inferring the identity of a microorganism directly from clinical material; (7) For detection of antibodies to microorganisms other than immunoglobulin G (IgG) or IgG assays when the results are not qualitative, or are used to determine immunity, or the assay is intended for use in matrices other than serum or plasma; (8) For noninvasive testing as defined in §812.3(k) of this chapter; and (9) For near patient testing (point of care). [65 FR 2313, Jan. 14, 2000] (a) Identification. A manual algesimeter is a mechanical device intended to determine a patient's sensitivity to pain after administration of an anesthetic agent, e.g., by pricking with a sharp point. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. The device is also exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [54 FR 25048, June 12, 1989, as amended at 66 FR 38793, July 25, 2001] (a) Identification. A powered algesimeter is a device using electrical stimulation intended to determine a patient's sensitivity to pain after administration of an anesthetic agent. (b) Classification. Class II (performance standards). (a) Identification. An argon gas analyzer is a device intended to measure the concentration of argon in a gas mixture to aid in determining the patient's ventilatory status. The device may use techniques such as mass spectrometry or thermal conductivity. (b) Classification. Class II (performance standards). (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples from a patient for blood gas determinations. The kit may include a syringe, needle, cork, and heparin. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38793, July 25, 2001] (a) Identification. An indwelling blood oxyhemoglobin concentration analyzer is a photoelectric device used to measure, in vivo, the oxygen-carrying capacity of hemoglobin in blood to aid in determining the patient's physiological status. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of PDP is required. A PMA or notice of completion of a PDP is required to be filed with the Food and Drug Administration on or before September 21, 2004, for any indwelling blood oxyhemoglobin concentration analyzer that was in commercial distribution before May 28, 1976, or that has, on or before September 21, 2004, been found to be substantially equivalent to an indwelling blood oxyhemoglobin concentration analyzer that was in commercial distribution before May 28, 1976. Any other indwelling blood oxyhemoglobin concentration analyzer shall have an approved PMA or declared completed PDP in effect before being placed in commercial distribution. [47 FR 31142, July 16, 1982, as amended at 52 FR 17735, May 11, 1987; 52 FR 22577, June 12, 1987; 69 FR 34920, June 23, 2004] (a) Identification. An indwelling blood carbon dioxide partial pressure PCO2 analyzer is a device that consists of a catheter-tip PCO2 transducer (e.g., PCO2 electrode) and that is used to measure, in vivo, the partial pressure of carbon dioxide in blood to aid in determining the patient's circulatory, ventilatory, and metabolic status. (b) Classification. Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Indwelling Blood Gas Analyzers; Final Guidance for Industry and FDA.” [47 FR 31142, July 16, 1982; 47 FR 40410, Sept. 14, 1982, as amended at 52 FR 17735, May 11, 1987; 66 FR 57368, Nov. 15, 2001] (a) Identification. An indwelling blood hydrogen ion concentration (pH) analyzer is a device that consists of a catheter-tip pH electrode and that is used to measure, in vivo, the hydrogen ion concentration (pH) in blood to aid in determining the patient's acid-base balance. (b) Classification. Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Indwelling Blood Gas Analyzers; Final Guidance for Industry and FDA.” [47 FR 31142, July 16, 1982, as amended at 52 FR 17735, May 11, 1987; 66 FR 57368, Nov. 15, 2001] (a) Identification. An indwelling blood oxygen partial pressure (PO2) analyzer is a device that consists of a catheter-tip PO2 transducer (e.g., PO2 electrode) and that is used to measure, in vivo, the partial pressure of oxygen in blood to aid in determining the patient's circulatory, ventilatory, and metabolic status. (b) Classification. Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Indwelling Blood Gas Analyzers; Final Guidance for Industry and FDA.” [47 FR 31142, July 16, 1982; 47 FR 40410, Sept. 14, 1982, as amended at 52 FR 17735, May 11, 1987; 66 FR 57368, Nov. 15, 2001] (a) Identification. A carbon dioxide gas analyzer is a device intended to measure the concentration of carbon dioxide in a gas mixture to aid in determining the patient's ventilatory, circulatory, and metabolic status. The device may use techniques such as chemical titration, absorption of infrared radiation, gas chromatography, or mass spectrometry. (b) Classification. Class II (performance standards). (a) Identification. A carbon monoxide gas analyzer is a device intended to measure the concentration of carbon monoxide in a gas mixture to aid in determining the patient's ventilatory status. The device may use techniques such as infrared absorption or gas chromatography. (b) Classification. Class II (performance standards). (a) Identification. An enflurane gas analyzer is a device intended to measure the concentration of enflurane anesthetic in a gas mixture. (b) Classification. Class II (performance standards). (a) Identification. A gas collection vessel is a container-like device intended to collect a patient's exhaled gases for subsequent analysis. It does not include a sampling pump. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38793, July 25, 2001] (a) Identification. A halothane gas analyzer is a device intended to measure the concentration of halothane anesthetic in a gas mixture. The device may use techniques such as mass spectrometry or absorption of infrared or ultraviolet radiation. (b) Classification. Class II (performance standards). (a) Identification. A helium gas analyzer is a device intended to measure the concentration of helium in a gas mixture during pulmonary function testing. The device may use techniques such as thermal conductivity, gas chromatography, or mass spectrometry. (b) Classification. Class II (performance standards). (a) Identification. A neon gas analyzer is a device intended to measure the concentration of neon in a gas mixture exhaled by a patient. The device may use techniques such as mass spectrometry or thermal conductivity. (b) Classification. Class II (performance standards). (a) Identification. A nitrogen gas analyzer is a device intended to measure the concentration of nitrogen in respiratory gases to aid in determining a patient's ventilatory status. The device may use techniques such as gas chromatography or mass spectrometry. (b) Classification. Class II (performance standards). (a) Identification. A nitrous oxide gas analyzer is a device intended to measure the concentration of nitrous oxide anesthetic in a gas mixture. The device may use techniques such as infrared absorption or mass spectrometry. (b) Classification. Class II (performance standards). (a) Identification. An oxygen gas analyzer is a device intended to measure the concentration of oxygen in respiratory gases by techniques such as mass spectrometry, polarography, thermal conductivity, or gas chromatography. This generic type of device also includes paramagnetic analyzers. (b) Classification. Class II (performance standards). (a) Identification. An oxygen uptake computer is a device intended to compute the amount of oxygen consumed by a patient and may include components for determining expired gas volume and composition. (b) Classification. Class II (performance standards). (a) Identification. A pressure plethysmograph is a device used to determine a patient's airway resistance and lung volumes by measuring pressure changes while the patient is in an airtight box. (b) Classification. Class II (performance standards). (a) Identification. A volume plethysmograph is an airtight box, in which a patient sits, that is used to determine the patient's lung volume changes. (b) Classification. Class II (performance standards). (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount of pressure produced in a patient's airway during maximal inspiration. (b) Classification. Class II (performance standards). (a) Identification. A rhinoanemometer is a device used to quantify the amount of nasal congestion by measuring the airflow through, and differential pressure across, a patient's nasal passages. (b) Classification. Class II (performance standards). (a) Identification. A diagnostic spirometer is a device used in pulmonary function testing to measure the volume of gas moving in or out of a patient's lungs. (b) Classification. Class II (performance standards). (a) Identification. A monitoring spirometer is a device used to measure continuously a patient's tidal volume (volume of gas inhaled by the patient during each respiration cycle) or minute volume (the tidal volume multiplied by the rate of respiration for 1 minute) for the evaluation of the patient's ventilatory status. (b) Classification. Class II (performance standards). (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's maximum ventilatory flow rate. (b) Classification. Class II (performance standards). (a) Identification. A gas volume calibrator is a device that is intended for medical purposes and that is used to calibrate the output of gas volume measurement instruments by delivering a known gas volume. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38793, July 25, 2001] (a) Identification. A pulmonary-function data calculator is a device used to calculate pulmonary-function values based on actual physical data obtained during pulmonary-function testing. (b) Classification. Class II (performance standards). (a) Identification. A predictive pulmonary-function value calculator is a device used to calculate normal pulmonary-function values based on empirical equations. (b) Classification. Class II (performance standards). (a) Identification. A diagnostic pulmonary-function interpretation calculator is a device that interprets pulmonary study data to determine clinical significance of pulmonary-function values. (b) Classification. Class II (performance standards). (a) Identification. An esophageal stethoscope is a nonpowered device that is inserted into a patient's esophagus to enable the user to listen to heart and breath sounds. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to §868.9. [47 FR 31142, July 16, 1982, as amended at 65 FR 2313, Jan. 14, 2000] (a) Identification. An esophageal stethoscope with electrical conductors is a device that is inserted into the esophagus to listen to a patient's heart and breath sounds and to monitor electrophysiological signals. The device may also incorporate a thermistor for temperature measurement. (b) Classification. Class II (performance standards). (a) Identification. A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and other physiological sounds. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38793, July 25, 2001] (a) Identification. A switching valve (ploss) is a three-way valve located between a stethoscope placed over the heart, a blood pressure cuff, and an earpiece. The valve allows the user to eliminate one sound channel and listen only to a patient's heart or korotkoff (blood pressure) sounds through the other channel. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. The device is also exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38793, July 25, 2001] (a) Identification. A water vapor analyzer is a device intended to measure the concentration of water vapor in a patient's expired gases by using techniques such as mass spectrometry. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38793, July 25, 2001] (a) Identification. An ultrasonic air embolism monitor is a device used to detect air bubbles in a patient's blood stream. It may use Doppler or other ultrasonic principles. (b) Classification. Class II (performance standards). (a) Identification. A bourdon gauge flowmeter is a device intended for medical purposes that is used in conjunction with respiratory equipment to sense gas pressure. The device is calibrated to indicate gas flow rate when the outflow is open to the atmosphere. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. An uncompensated thorpe tube flowmeter is a device intended for medical purposes that is used to indicate and control gas flow rate accurately. The device includes a vertically mounted tube and is calibrated when the outlet of the flowmeter is open to the atmosphere. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A compensated thorpe tube flowmeter is a device intended for medical purposes that is used to control and measure gas flow rate accurately. The device includes a vertically mounted tube, with the outlet of the flowmeter calibrated to a reference pressure. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A gas calibration flowmeter is a device intended for medical purposes that is used to calibrate flowmeters and accurately measure gas flow. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A breathing (ventilatory) frequency monitor is a device intended to measure or monitor a patient's respiratory rate. The device may provide an audible or visible alarm when the respiratory rate, averaged over time, is outside operator settable alarm limits. This device does not include the apnea monitor classified in §868.2377. (b) Classification. Class II (performance standards). [47 FR 31142, July 16, 1982, as amended at 67 FR 46852, July 17, 2002] (a) Identification. An apnea monitor is a complete system intended to alarm primarily upon the cessation of breathing timed from the last detected breath. The apnea monitor also includes indirect methods of apnea detection such as monitoring of heart rate and other physiological parameters linked to the presence or absence of adequate respiration. (b) Classification. Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Apnea Monitors; Guidance for Industry and FDA.” [67 FR 46852, July 17, 2002] (a) Identification. The nitric oxide analyzer is a device intended to measure the concentration of nitric oxide in respiratory gas mixtures during administration of nitric oxide. (b) Classification. Class II. The special control for this device is FDA's “Guidance Document for Premarket Notification Submissions for Nitric Oxide Administration Apparatus, Nitric Oxide Analyzer, and Nitrogen Dioxide Analyzer.” [65 FR 14465, Mar. 3, 2000] (a) Identification. The nitrogen dioxide analyzer is a device intended to measure the concentration of nitrogen dioxide in respiratory gas mixtures during administration of nitric oxide. (b) Classification. Class II. The special control for this device is FDA's “Guidance Document for Premarket Notification Submissions for Nitric Oxide Administration Apparatus, Nitric Oxide Analyzer, and Nitrogen Dioxide Analyzer.” [65 FR 11465, Mar. 3, 2000] (a) Identification. A lung water monitor is a device used to monitor the trend of fluid volume changes in a patient's lung by measuring changes in thoracic electrical impedance (resistance to alternating current) by means of electrodes placed on the patient's chest. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. A PMA or a notice of completion of a PDP for a device is required to be filed with the Food and Drug Administration on or before July 12, 2000, for any lung water monitor that was in commercial distribution before May 28, 1976, or that has, on or before July 12, 2000, been found to be substantially equivalent to a lung water monitor that was in commercial distribution before May 28, 1976. Any other lung water monitor device shall have an approved PMA or declared completed PDP in effect before being placed in commercial distribution. [47 FR 31142, July 16, 1982, as amended at 52 FR 17735, May 11, 1987; 65 FR 19834, Apr. 13, 2000] (a) Identification. A cutaneous carbon dioxide (PcCO2) monitor is a noninvasive heated sensor and a pH-sensitive glass electrode placed on a patient's skin, which is intended to monitor relative changes in a hemodynamically stable patient's cutaneous carbon dioxide tension as an adjunct to arterial carbon dioxide tension measurement. (b) Classification. Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Cutaneous Carbon Dioxide (PcCO2) and Oxygen (PcO2) Monitors; Guidance for Industry and FDA.” See §868.1(e) for the availability of this guidance document. [54 FR 27160, June 28, 1989, as amended at 67 FR 76681, Dec. 13, 2002] (a) Identification. A cutaneous oxygen (PcO2) monitor is a noninvasive, heated sensor (e.g., a Clark-type polargraphic electrode) placed on the patient's skin that is intended to monitor relative changes in the cutaneous oxygen tension. (b) Classification. Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Cutaneous Carbon Dioxide (PcCO2) and Oxygen (PcO2) Monitors; Guidance for Industry and FDA.” See §868.1(e) for the availability of this guidance document. [67 FR 76681, Dec. 13, 2002] (a) Identification. A pneumotachometer is a device intended for medical purposes that is used to determine gas flow by measuring the pressure differential across a known resistance. The device may use a set of capillaries or a metal screen for the resistive element. (b) Classification. Class II (performance standards). (a) Identification. An airway pressure monitor is a device used to measure the pressure in a patient's upper airway. The device may include a pressure gauge and an alarm. (b) Classification. Class II (performance standards). (a) Identification. A gas pressure gauge (e.g., bourdon tube pressure gauge) is a device intended for medical purposes that is used to measure gas pressure in a medical gas delivery system. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A gas pressure calibrator is a device intended for medical purposes that is used to calibrate pressure-measuring instruments by generating a known gas pressure. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A pressure regulator is a device, often called a pressure-reducing valve, that is intended for medical purposes and that is used to convert a medical gas pressure from a high variable pressure to a lower, more constant working pressure. This device includes mechanical oxygen regulators. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. An electrical peripheral nerve stimulator (neuromuscular blockade monitor) is a device used to apply an electrical current to a patient to test the level of pharmacological effect of anesthetic drugs and gases. (b) Classification. Class II (performance standards). (a) Identification. A differential pressure transducer is a two-chambered device intended for medical purposes that is often used during pulmonary function testing. It generates an electrical signal for subsequent display or processing that is proportional to the difference in gas pressures in the two chambers. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A gas flow transducer is a device intended for medical purposes that is used to convert gas flow rate into an electrical signal for subsequent display or processing. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1119, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A gas pressure transducer is a device intended for medical purposes that is used to convert gas pressure into an electrical signal for subsequent display or processing. (b) Classification. Class I. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996] (a) Identification. An emergency airway needle is a device intended to puncture a patient's cricothyroid membrane to provide an emergency airway during upper airway obstruction. (b) Classification. Class II (performance standards). (a) Identification. A nasopharyngeal airway is a device used to aid breathing by means of a tube inserted into a patient's pharynx through the nose to provide a patent airway. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. An oropharyngeal airway is a device inserted into a patient's pharynx through the mouth to provide a patent airway. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. The device is a raised, rounded pad that, in the event of choking on a foreign body, can be applied to the abdomen and pushed upward to generate expulsion pressure to remove the obstruction to relieve acute upper airway obstruction. (b) Classification. Class II (special controls) (“Class II Special Control Guidance Document for Acute Upper Airway Obstruction Devices”). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to §868.9. [65 FR 39099, June 23, 2000; 65 FR 47669, Aug. 3, 2000] (a) Identification. An anesthesia conduction catheter is a flexible tubular device used to inject local anesthetics into a patient and to provide continuous regional anesthesia. (b) Classification. Class II (performance standards). (a) Identification. An anesthesia conduction filter is a microporous filter used while administering to a patient injections of local anesthetics to minimize particulate (foreign material) contamination of the injected fluid. (b) Classification. Class II (performance standards). (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or local anesthesia. The device may contain syringes, needles, and drugs. (b) Classification. Class II (performance standards). (a) Identification. An anesthesia conduction needle is a device used to inject local anesthetics into a patient to provide regional anesthesia. (b) Classification. Class II (performance standards). (a) Gas machine for anesthesia—(1) Identification. A gas machine for anesthesia is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation. The device may include a gas flowmeter, vaporizer, ventilator, breathing circuit with bag, and emergency air supply. (2) Classification. Class II (performance standards). (b) Gas machine for analgesia—(1) Identification. A gas machine for analgesia is a device used to administer to a patient an analgesic agent, such as a nitrous oxide-oxygen mixture (maximum concentration of 70 percent nitrous oxide). (2) Classification. Class II (performance standards). (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be used in conjunction with a ventilator or other breathing gas administration system. (b) Classification. Class II. The special control for this device is FDA's “Guidance Document for Premarket Notification Submissions for Nitric Oxide Administration Apparatus, Nitric Oxide Analyzer, and Nitrogen Dioxide Analyzer.” [65 FR 11465, Mar. 3, 2000] (a) Identification. A laryngotracheal topical anesthesia applicator is a device used to apply topical anesthetics to a patient's laryngotracheal area. (b) Classification. Class II (performance standards). (a) Identification. A rocking bed is a device intended for temporary use to help patient ventilation (breathing) by repeatedly tilting the patient, thereby using the weight of the abdominal contents to move the diaphragm. (b) Classification. Class II (performance standards). (a) Identification. A blow bottle is a device that is intended for medical purposes to induce a forced expiration from a patient. The patient blows into the device to move a column of water from one bottle to another. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38794, July 25, 2001] (a) Identification. An anesthesia breathing circuit is a device that is intended to administer medical gases to a patient during anesthesia. It provides both an inhalation and exhalation route and may include a connector, adaptor, and Y-piece. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A breathing circuit circulator is a turbine device that is attached to a closed breathing circuit and that is intended to circulate anesthetic gases continuously by maintaining the unidirectional valves in an open position and reducing mechanical dead space and resistance in the breathing circuit. (b) Classification. Class II (performance standards). (a) Identification. A breathing circuit bacterial filter is a device that is intended to remove microbiological and particulate matter from the gases in the breathing circuit. (b) Classification. Class II (performance standards). (a) Identification. A breathing system heater is a device that is intended to warm breathing gases before they enter a patient's airway. The device may include a temperature controller. (b) Classification. Class II (performance standards). (a) Identification. A breathing tube support is a device that is intended to support and anchor a patient's breathing tube(s). (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38794, July 25, 2001] (a) Identification. A carbon dioxide absorbent is a device intended for medical purposes that consists of an absorbent material (e.g., soda lime) that is intended to remove carbon dioxide from the gases in the breathing circuit. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A carbon dioxide absorber is a device that is intended for medical purposes and that is used in a breathing circuit as a container for carbon dioxide absorbent. It may include a canister and water drain. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A reservoir bag is a device, usually made of conductive rubber, intended for use in a breathing circuit as a reservoir for breathing gas and to assist, control, or monitor a patient's ventilation. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38794, July 25, 2001] (a) Identification. A breathing gas mixer is a device intended for use in conjunction with a respiratory support apparatus to control the mixing of gases that are to be breathed by a patient. (b) Classification. Class II (performance standards). (a) Identification. A nasal oxygen cannula is a two-pronged device used to administer oxygen to a patient through both nostrils. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 59 FR 63007, Dec. 7, 1994; 66 FR 38794, July 25, 2001] (a) Identification. A nasal oxygen catheter is a device intended to be inserted through a patient's nostril to administer oxygen. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 59 FR 63007, Dec. 7, 1994; 66 FR 38794, July 25, 2001] (a) Identification. A posture chair for cardiac or pulmonary treatment is a device intended to assist in the rehabilitation and mobilization of patients with chronic heart or lung disease. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38794, July 25, 2001] (a) Identification. A heat and moisture condenser (artificial nose) is a device intended to be positioned over a tracheotomy (a surgically created opening in the throat) or tracheal tube (a tube inserted into the trachea) to warm and humidify gases breathed in by a patient. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. An electroanesthesia apparatus is a device used for the induction and maintenance of anesthesia during surgical procedures by means of an alternating or pulsed electric current that is passed through electrodes fixed to a patient's head. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. A PMA or notice of completion of a PDP is required to be filed with the Food and Drug Administration on or before December 26, 1996 for any electroanesthesia apparatus that was in commercial distribution before May 28, 1976, or that has, on or before December 26, 1996 been found to be substantially equivalent to an electroanesthesia apparatus that was in commercial distribution before May 28, 1976. Any other electroanesthesia apparatus shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution. [47 FR 31142, July 16, 1982, as amended at 52 FR 17735, May 11, 1987; 61 FR 50706, Sept. 27, 1996] (a) Identification. An ether hook is a device that fits inside a patient's mouth and that is intended to deliver vaporized ether. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38795, July 25, 2001] (a) Identification. A gas-scavenging apparatus is a device intended to collect excess anesthetic, analgesic, or trace gases or vapors from a patient's breathing system, ventilator, or extracorporeal pump-oxygenator, and to conduct these gases out of the area by means of an exhaust system. (b) Classification. Class II (performance standards). (a) Identification. A portable oxygen generator is a device that is intended to release oxygen for respiratory therapy by means of either a chemical reaction or physical means (e.g., a molecular sieve). (b) Classification. Class II (performance standards). (a) Identification. A respiratory gas humidifier is a device that is intended to add moisture to, and sometimes to warm, the breathing gases for administration to a patient. Cascade, gas, heated, and prefilled humidifiers are included in this generic type of device. (b) Classification. Class II (performance standards). (a) Identification. A therapeutic humidifier for home use is a device that adds water vapor to breathing gases and that is intended for respiratory therapy or other medical purposes. The vapor produced by the device pervades the area surrounding the patient, who breathes the vapor during normal respiration. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982; 47 FR 40410, Sept. 14, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A hyperbaric chamber is a device that is intended to increase the environmental oxygen pressure to promote the movement of oxygen from the environment to a patient's tissue by means of pressurization that is greater than atmospheric pressure. This device does not include topical oxygen chambers for extremities (§878.5650). (b) Classification. Class II (performance standards). (a) Identification. A flexible laryngoscope is a fiberoptic device used to examine and visualize a patient's upper airway and aid placement of a tracheal tube. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 41107, Sept. 17, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A rigid laryngoscope is a device used to examine and visualize a patient's upper airway and aid placement of a tracheal tube. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9 [47 FR 41107, Sept. 17, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. An anesthetic gas mask is a device, usually made of conductive rubber, that is positioned over a patient's nose or mouth to direct anesthetic gases to the upper airway. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 41107, Sept. 17, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's face. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 41107, Sept. 17, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38795, July 25, 2001] (a) Identification. A nonrebreathing mask is a device fitting over a patient's face to administer oxygen. It utilizes one-way valves to prevent the patient from rebreathing previously exhaled gases. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. An oxygen mask is a device placed over a patient's nose, mouth, or tracheostomy to administer oxygen or aerosols. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A scavenging mask is a device positioned over a patient's nose to deliver anesthetic or analgesic gases to the upper airway and to remove excess and exhaled gas. It is usually used during dentistry. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A venturi mask is a device containing an air-oxygen mixing mechanism that dilutes 100 percent oxygen to a predetermined concentration and delivers the mixed gases to a patient. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A membrane lung for long-term pulmonary support is a device used to provide to a patient extracorporeal blood oxygenation for longer than 24 hours. (b) Classification. Class III (premarket approval). (c) Date PMA or notice of completion of a PDP is required. No effective date has been established of the requirement for premarket approval. See §868.3. [47 FR 31142, July 16, 1982, as amended at 52 FR 17735, May 11, 1987] (a) Identification. A breathing mouthpiece is a rigid device that is inserted into a patient's mouth and that connects with diagnostic or therapeutic respiratory devices. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to §868.9. [47 FR 31142, July 16, 1982, as amended at 65 FR 2313, Jan. 14, 2000] (a) Identification. A nebulizer is a device intended to spray liquids in aerosol form into gases that are delivered directly to the patient for breathing. Heated, ultrasonic, gas, venturi, and refillable nebulizers are included in this generic type of device. (b) Classification. Class II (performance standards). (a) Identification. A medicinal nonventilatory nebulizer (atomizer) is a device that is intended to spray liquid medication in aerosol form into the air that a patient will breathe. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to §868.9. [47 FR 31142, July 16, 1982, as amended at 65 FR 2313, Jan. 14, 2000] (a) Identification. An esophageal obturator is a device inserted through a patient's mouth to aid ventilation of the patient during emergency resuscitation by occluding (blocking) the esophagus, thereby permitting positive pressure ventilation through the trachea. The device consists of a closed-end semirigid esophageal tube that is attached to a face mask. (b) Classification. Class II (performance standards). (a) Identification. A portable liquid oxygen unit is a portable, thermally insulated container of liquid oxygen that is intended to supplement gases to be inhaled by a patient, is sometimes accompanied by tubing and an oxygen mask. An empty portable liquid oxygen unit is a device, while the oxygen contained therein is a drug. (b) Classification. Class II (performance standards). (a) Identification. A powered percussor is a device that is intended to transmit vibration through a patient's chest wall to aid in freeing mucus deposits in the lung in order to improve bronchial drainage and that may be powered by electricity or compressed gas. (b) Classification. Class II (performance standards). (a) Identification. A rebreathing device is a device that enables a patient to rebreathe exhaled gases. It may be used in conjunction with pulmonary function testing or for increasing minute ventilation. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to §868.9. [47 FR 31142, July 16, 1982, as amended at 65 FR 2313, Jan. 14, 2000] (a) Identification. An incentive spirometer is a device that indicates a patient's breathing volume or flow and that provides an incentive to the patient to improve his or her ventilation. (b) Classification. Class II (performance standards). (a) Identification. A nonpowered oxygen tent is a device that encloses a patient's head and upper body to contain oxygen delivered to the patient for breathing. This generic type of device includes infant oxygen hoods. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to §868.9. [47 FR 31142, July 16, 1982, as amended at 65 FR 2313, Jan. 14, 2000] (a) Identification. An electrically powered oxygen tent is a device that encloses a patient's head and, by means of an electrically powered unit, administers breathing oxygen and controls the temperature and humidity of the breathing gases. This generic type device includes the pediatric aerosol tent. (b) Classification. Class II (performance standards). (a) Identification. A bronchial tube is a device used to differentially intubate a patient's bronchus (one of the two main branches of the trachea leading directly to the lung) in order to isolate a portion of lung distal to the tube. (b) Classification. Class II (performance standards). (a) Identification. A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway. (b) Classification. Class II (performance standards). (a) Identification. A tracheal/bronchial differential ventilation tube is a device used to isolate the left or the right lung of a patient for anesthesia or pulmonary function testing. (b) Classification. Class II (performance standards). (a) Identification. An inflatable tracheal tube cuff is a device used to provide an airtight seal between a tracheal tube and a patient's trachea. (b) Classification. Class II (performance standards). (a) Identification. A cuff spreader is a device used to install tracheal tube cuffs on tracheal or tracheostomy tubes. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38795, July 25, 2001] (a) Identification. A tracheal tube fixation device is a device used to hold a tracheal tube in place, usually by means of straps or pinch rings. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. Tube introduction forceps (e.g., Magill forceps) are a right-angled device used to grasp a tracheal tube and place it in a patient's trachea. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A tracheal tube stylet is a device used temporarily to make rigid a flexible tracheal tube to aid its insertion into a patient. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A tracheal tube cleaning brush is a device consisting of a brush with plastic bristles intended to clean tracheal cannula devices after their removal from patients. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [51 FR 40388, Nov. 6, 1986, as amended at 66 FR 38795, July 25, 2001] (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a surgical opening of the trachea to facilitate ventilation to the lungs. The cuff may be a separate or integral part of the tracheostomy tube and is, when inflated, intended to establish a seal between the tracheal wall and the tracheostomy tube. The cuff is used to prevent the patient's aspiration of substances, such as blood or vomit, or to provide a means for positive-pressure ventilation of the patient. This device is made of either stainless steel or plastic. (b) Classification. Class II. [51 FR 40389, Nov. 6, 1986] (a) Identification. An airway connector is a device intended to connect a breathing gas source to a tracheal tube, tracheostomy tube, or mask. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. A dental protector is a device intended to protect a patient's teeth during manipulative procedures within a patient's oral cavity. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38795, July 25, 2001] (a) Identification. An autotransfusion apparatus is a device used to collect and reinfuse the blood lost by a patient due to surgery or trauma. (b) Classification. Class II (performance standards). (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended to deliver pressurized medical gases. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38796, July 25, 2001] (a) Identification. A nonrebreathing valve is a one-way valve that directs breathing gas flow to the patient and vents exhaled gases into the atmosphere. (b) Classification. Class II (performance standards). (a) Identification. An anesthetic vaporizer is a device used to vaporize liquid anesthetic and deliver a controlled amount of the vapor to the patient. (b) Classification. Class II (performance standards). (a) Identification. A continuous ventilator (respirator) is a device intended to mechanically control or assist patient breathing by delivering a predetermined percentage of oxygen in the breathing gas. Adult, pediatric, and neonatal ventilators are included in this generic type of device. (b) Classification. Class II (performance standards). (a) Identification. A noncontinuous ventilator (intermittent positive pressure breathing-IPPB) is a device intended to deliver intermittently an aerosol to a patient's lungs or to assist a patient's breathing. (b) Classification. Class II (performance standards). (a) Identification. A manual emergency ventilator is a device, usually incorporating a bag and valve, intended to provide emergency respiratory support by means of a face mask or a tube inserted into a patient's airway. (b) Classification. Class II (performance standards). (a) Identification. A powered emergency ventilator is a demand valve or inhalator intended to provide emergency respiratory support by means of a face mask or a tube inserted into a patient's airway. (b) Classification. Class II (performance standards). (a) Identification. An external negative pressure ventilator (e.g., iron lung, cuirass) is a device chamber that is intended to support a patient's ventilation by alternately applying and releasing external negative pressure over the diaphragm and upper trunk of the patient. (b) Classification. Class II (performance standards). (a) Identification. An intermittent mandatory ventilation (IMV) attachment is a device attached to a mechanical ventilator that allows spontaneous breathing by a patient while providing mechanical ventilation at a preset rate. (b) Classification. Class II (performance standards). (a) Identification. A positive end expiratory pressure (PEEP) breathing attachment is a device attached to a ventilator that is used to elevate pressure in a patient's lungs above atmospheric pressure at the end of exhalation. (b) Classification. Class II (performance standards). (a) Identification. Ventilator tubing is a device intended for use as a conduit for gases between a ventilator and a patient during ventilation of the patient. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38796, July 25, 2001] (a) Identification. A tee drain (water trap) is a device intended to trap and drain water that collects in ventilator tubing during respiratory therapy, thereby preventing an increase in breathing resistance. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1120, Jan. 16, 1996; 66 FR 38796, July 25, 2001] (a) Identification. An anesthetic cabinet, table, or tray is a device intended to store anesthetic equipment and drugs. The device is usually constructed to eliminate build-up of static electrical charges. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38796, July 25, 2001] (a) Identification. A cardiopulmonary emergency cart is a device intended to store and transport resuscitation supplies for emergency treatment. The device does not include any equipment used in cardiopulmonary resuscitation. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. The device is also exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38796, July 25, 2001] (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. The device is also exempt from the current good manufacturing practice regulations in part 820 of this chapter, with the exception of §820.180, with respect to general requirements concerning records, and §820.198, with respect to complaint files. [47 FR 31142, July 16, 1982, as amended at 54 FR 25048, June 12, 1989; 66 FR 38796, July 25, 2001] (a) Identification. A portable air compressor is a device intended to provide compressed air for medical purposes, e.g., to drive ventilators and other respiratory devices. (b) Classification. Class II (performance standards). (a) Identification. A calibration gas is a device consisting of a container of gas of known concentration intended to calibrate medical gas concentration measurement devices. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1121, Jan. 16, 1996; 66 FR 38796, July 25, 2001] (a) Identification. An anesthesia stool is a device intended for use as a stool for the anesthesiologist in the operating room. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 54 FR 25049, June 12, 1989; 66 FR 38796, July 25, 2001] (a) Identification. A tracheobronchial suction catheter is a device used to aspirate liquids or semisolids from a patient's upper airway. (b) Classification. Class 1 (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to §868.9. [47 FR 31142, July 16, 1982, as amended at 65 FR 2314, Jan. 14, 2000] (a) Identification. A patient position support is a device intended to maintain the position of an anesthetized patient during surgery. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1121, Jan. 16, 1996; 66 FR 38796, July 25, 2001] (a) Identification. A medical gas yoke assembly is a device intended to connect medical gas cylinders to regulators or needle valves to supply gases for anesthesia or respiratory therapy. The device may include a particulate filter. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in §868.9. [47 FR 31142, July 16, 1982, as amended at 61 FR 1121, Jan. 16, 1996; 66 FR 38796, July 25, 2001]
Title 21: Food and Drugs
PART 868—ANESTHESIOLOGY DEVICES
Section Contents
§ 868.1 Scope.
§ 868.3 Effective dates of requirement for premarket approval.
§ 868.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).
§ 868.1030 Manual algesimeter.
§ 868.1040 Powered algesimeter.
§ 868.1075 Argon gas analyzer.
§ 868.1100 Arterial blood sampling kit.
§ 868.1120 Indwelling blood oxyhemoglobin concentration analyzer.
§ 868.1150 Indwelling blood carbon dioxide partial pressure (PCO2) analyzer.
§ 868.1170 Indwelling blood hydrogen ion concentration (pH) analyzer.
§ 868.1200 Indwelling blood oxygen partial pressure (PO2) analyzer.
§ 868.1400 Carbon dioxide gas analyzer.
§ 868.1430 Carbon monoxide gas analyzer.
§ 868.1500 Enflurane gas analyzer.
§ 868.1575 Gas collection vessel.
§ 868.1620 Halothane gas analyzer.
§ 868.1640 Helium gas analyzer.
§ 868.1670 Neon gas analyzer.
§ 868.1690 Nitrogen gas analyzer.
§ 868.1700 Nitrous oxide gas analyzer.
§ 868.1720 Oxygen gas analyzer.
§ 868.1730 Oxygen uptake computer.
§ 868.1750 Pressure plethysmograph.
§ 868.1760 Volume plethysmograph.
§ 868.1780 Inspiratory airway pressure meter.
§ 868.1800 Rhinoanemometer.
§ 868.1840 Diagnostic spirometer.
§ 868.1850 Monitoring spirometer.
§ 868.1860 Peak-flow meter for spirometry.
§ 868.1870 Gas volume calibrator.
§ 868.1880 Pulmonary-function data calculator.
§ 868.1890 Predictive pulmonary-function value calculator.
§ 868.1900 Diagnostic pulmonary-function interpretation calculator.
§ 868.1910 Esophageal stethoscope.
§ 868.1920 Esophageal stethoscope with electrical conductors.
§ 868.1930 Stethoscope head.
§ 868.1965 Switching valve (ploss).
§ 868.1975 Water vapor analyzer.
§ 868.2025 Ultrasonic air embolism monitor.
§ 868.2300 Bourdon gauge flowmeter.
§ 868.2320 Uncompensated thorpe tube flowmeter.
§ 868.2340 Compensated thorpe tube flowmeter.
§ 868.2350 Gas calibration flowmeter.
§ 868.2375 Breathing frequency monitor.
§ 868.2377 Apnea monitor.
§ 868.2380 Nitric oxide analyzer.
§ 868.2385 Nitrogen dioxide analyzer.
§ 868.2450 Lung water monitor.
§ 868.2480 Cutaneous carbon dioxide (PcCO2) monitor.
§ 868.2500 Cutaneous oxygen (PcO2) monitor.
§ 868.2550 Pneumotachometer.
§ 868.2600 Airway pressure monitor.
§ 868.2610 Gas pressure gauge.
§ 868.2620 Gas pressure calibrator.
§ 868.2700 Pressure regulator.
§ 868.2775 Electrical peripheral nerve stimulator.
§ 868.2875 Differential pressure transducer.
§ 868.2885 Gas flow transducer.
§ 868.2900 Gas pressure transducer.
§ 868.5090 Emergency airway needle.
§ 868.5100 Nasopharyngeal airway.
§ 868.5110 Oropharyngeal airway.
§ 868.5115 Device to relieve acute upper airway obstruction.
§ 868.5120 Anesthesia conduction catheter.
§ 868.5130 Anesthesia conduction filter.
§ 868.5140 Anesthesia conduction kit.
§ 868.5150 Anesthesia conduction needle.
§ 868.5160 Gas machine for anesthesia or analgesia.
§ 868.5165 Nitric oxide administration apparatus.
§ 868.5170 Laryngotracheal topical anesthesia applicator.
§ 868.5180 Rocking bed.
§ 868.5220 Blow bottle.
§ 868.5240 Anesthesia breathing circuit.
§ 868.5250 Breathing circuit circulator.
§ 868.5260 Breathing circuit bacterial filter.
§ 868.5270 Breathing system heater.
§ 868.5280 Breathing tube support.
§ 868.5300 Carbon dioxide absorbent.
§ 868.5310 Carbon dioxide absorber.
§ 868.5320 Reservoir bag.
§ 868.5330 Breathing gas mixer.
§ 868.5340 Nasal oxygen cannula.
§ 868.5350 Nasal oxygen catheter.
§ 868.5365 Posture chair for cardiac or pulmonary treatment.
§ 868.5375 Heat and moisture condenser (artificial nose).
§ 868.5400 Electroanesthesia apparatus.
§ 868.5420 Ether hook.
§ 868.5430 Gas-scavenging apparatus.
§ 868.5440 Portable oxygen generator.
§ 868.5450 Respiratory gas humidifier.
§ 868.5460 Therapeutic humidifier for home use.
§ 868.5470 Hyperbaric chamber.
§ 868.5530 Flexible laryngoscope.
§ 868.5540 Rigid laryngoscope.
§ 868.5550 Anesthetic gas mask.
§ 868.5560 Gas mask head strap.
§ 868.5570 Nonrebreathing mask.
§ 868.5580 Oxygen mask.
§ 868.5590 Scavenging mask.
§ 868.5600 Venturi mask.
§ 868.5610 Membrane lung for long-term pulmonary support.
§ 868.5620 Breathing mouthpiece.
§ 868.5630 Nebulizer.
§ 868.5640 Medicinal nonventilatory nebulizer (atomizer).
§ 868.5650 Esophageal obturator.
§ 868.5655 Portable liquid oxygen unit.
§ 868.5665 Powered percussor.
§ 868.5675 Rebreathing device.
§ 868.5690 Incentive spirometer.
§ 868.5700 Nonpowered oxygen tent.
§ 868.5710 Electrically powered oxygen tent.
§ 868.5720 Bronchial tube.
§ 868.5730 Tracheal tube.
§ 868.5740 Tracheal/bronchial differential ventilation tube.
§ 868.5750 Inflatable tracheal tube cuff.
§ 868.5760 Cuff spreader.
§ 868.5770 Tracheal tube fixation device.
§ 868.5780 Tube introduction forceps.
§ 868.5790 Tracheal tube stylet.
§ 868.5795 Tracheal tube cleaning brush.
§ 868.5800 Tracheostomy tube and tube cuff.
§ 868.5810 Airway connector.
§ 868.5820 Dental protector.
§ 868.5830 Autotransfusion apparatus.
§ 868.5860 Pressure tubing and accessories.
§ 868.5870 Nonrebreathing valve.
§ 868.5880 Anesthetic vaporizer.
§ 868.5895 Continuous ventilator.
§ 868.5905 Noncontinuous ventilator (IPPB).
§ 868.5915 Manual emergency ventilator.
§ 868.5925 Powered emergency ventilator.
§ 868.5935 External negative pressure ventilator.
§ 868.5955 Intermittent mandatory ventilation attachment.
§ 868.5965 Positive end expiratory pressure breathing attachment.
§ 868.5975 Ventilator tubing.
§ 868.5995 Tee drain (water trap).
§ 868.6100 Anesthetic cabinet, table, or tray.
§ 868.6175 Cardiopulmonary emergency cart.
§ 868.6225 Nose clip.
§ 868.6250 Portable air compressor.
§ 868.6400 Calibration gas.
§ 868.6700 Anesthesia stool.
§ 868.6810 Tracheobronchial suction catheter.
§ 868.6820 Patient position support.
§ 868.6885 Medical gas yoke assembly.
Subpart A—General Provisions
top
§ 868.1 Scope.
top
§ 868.3 Effective dates of requirement for premarket approval.
top
§ 868.9 Limitations of exemptions from section 510(k) of the Federal Food, Drug, and Cosmetic Act (the act).
top
Subpart B—Diagnostic Devices
top
§ 868.1030 Manual algesimeter.
top
§ 868.1040 Powered algesimeter.
top
§ 868.1075 Argon gas analyzer.
top
§ 868.1100 Arterial blood sampling kit.
top
§ 868.1120 Indwelling blood oxyhemoglobin concentration analyzer.
top
§ 868.1150 Indwelling blood carbon dioxide partial pressure (PCO2) analyzer.
top
§ 868.1170 Indwelling blood hydrogen ion concentration (pH) analyzer.
top
§ 868.1200 Indwelling blood oxygen partial pressure (PO2) analyzer.
top
§ 868.1400 Carbon dioxide gas analyzer.
top
§ 868.1430 Carbon monoxide gas analyzer.
top
§ 868.1500 Enflurane gas analyzer.
top
§ 868.1575 Gas collection vessel.
top
§ 868.1620 Halothane gas analyzer.
top
§ 868.1640 Helium gas analyzer.
top
§ 868.1670 Neon gas analyzer.
top
§ 868.1690 Nitrogen gas analyzer.
top
§ 868.1700 Nitrous oxide gas analyzer.
top
§ 868.1720 Oxygen gas analyzer.
top
§ 868.1730 Oxygen uptake computer.
top
§ 868.1750 Pressure plethysmograph.
top
§ 868.1760 Volume plethysmograph.
top
§ 868.1780 Inspiratory airway pressure meter.
top
§ 868.1800 Rhinoanemometer.
top
§ 868.1840 Diagnostic spirometer.
top
§ 868.1850 Monitoring spirometer.
top
§ 868.1860 Peak-flow meter for spirometry.
top
§ 868.1870 Gas volume calibrator.
top
§ 868.1880 Pulmonary-function data calculator.
top
§ 868.1890 Predictive pulmonary-function value calculator.
top
§ 868.1900 Diagnostic pulmonary-function interpretation calculator.
top
§ 868.1910 Esophageal stethoscope.
top
§ 868.1920 Esophageal stethoscope with electrical conductors.
top
§ 868.1930 Stethoscope head.
top
§ 868.1965 Switching valve (ploss).
top
§ 868.1975 Water vapor analyzer.
top
Subpart C—Monitoring Devices
top
§ 868.2025 Ultrasonic air embolism monitor.
top
§ 868.2300 Bourdon gauge flowmeter.
top
§ 868.2320 Uncompensated thorpe tube flowmeter.
top
§ 868.2340 Compensated thorpe tube flowmeter.
top
§ 868.2350 Gas calibration flowmeter.
top
§ 868.2375 Breathing frequency monitor.
top
§ 868.2377 Apnea monitor.
top
§ 868.2380 Nitric oxide analyzer.
top
§ 868.2385 Nitrogen dioxide analyzer.
top
§ 868.2450 Lung water monitor.
top
§ 868.2480 Cutaneous carbon dioxide (PcCO2) monitor.
top
§ 868.2500 Cutaneous oxygen (PcO2) monitor.
top
§ 868.2550 Pneumotachometer.
top
§ 868.2600 Airway pressure monitor.
top
§ 868.2610 Gas pressure gauge.
top
§ 868.2620 Gas pressure calibrator.
top
§ 868.2700 Pressure regulator.
top
§ 868.2775 Electrical peripheral nerve stimulator.
top
§ 868.2875 Differential pressure transducer.
top
§ 868.2885 Gas flow transducer.
top
§ 868.2900 Gas pressure transducer.
top
Subparts D–E [Reserved]
top
Subpart F—Therapeutic Devices
top
§ 868.5090 Emergency airway needle.
top
§ 868.5100 Nasopharyngeal airway.
top
§ 868.5110 Oropharyngeal airway.
top
§ 868.5115 Device to relieve acute upper airway obstruction.
top
§ 868.5120 Anesthesia conduction catheter.
top
§ 868.5130 Anesthesia conduction filter.
top
§ 868.5140 Anesthesia conduction kit.
top
§ 868.5150 Anesthesia conduction needle.
top
§ 868.5160 Gas machine for anesthesia or analgesia.
top
§ 868.5165 Nitric oxide administration apparatus.
top
§ 868.5170 Laryngotracheal topical anesthesia applicator.
top
§ 868.5180 Rocking bed.
top
§ 868.5220 Blow bottle.
top
§ 868.5240 Anesthesia breathing circuit.
top
§ 868.5250 Breathing circuit circulator.
top
§ 868.5260 Breathing circuit bacterial filter.
top
§ 868.5270 Breathing system heater.
top
§ 868.5280 Breathing tube support.
top
§ 868.5300 Carbon dioxide absorbent.
top
§ 868.5310 Carbon dioxide absorber.
top
§ 868.5320 Reservoir bag.
top
§ 868.5330 Breathing gas mixer.
top
§ 868.5340 Nasal oxygen cannula.
top
§ 868.5350 Nasal oxygen catheter.
top
§ 868.5365 Posture chair for cardiac or pulmonary treatment.
top
§ 868.5375 Heat and moisture condenser (artificial nose).
top
§ 868.5400 Electroanesthesia apparatus.
top
§ 868.5420 Ether hook.
top
§ 868.5430 Gas-scavenging apparatus.
top
§ 868.5440 Portable oxygen generator.
top
§ 868.5450 Respiratory gas humidifier.
top
§ 868.5460 Therapeutic humidifier for home use.
top
§ 868.5470 Hyperbaric chamber.
top
§ 868.5530 Flexible laryngoscope.
top
§ 868.5540 Rigid laryngoscope.
top
§ 868.5550 Anesthetic gas mask.
top
§ 868.5560 Gas mask head strap.
top
§ 868.5570 Nonrebreathing mask.
top
§ 868.5580 Oxygen mask.
top
§ 868.5590 Scavenging mask.
top
§ 868.5600 Venturi mask.
top
§ 868.5610 Membrane lung for long-term pulmonary support.
top
§ 868.5620 Breathing mouthpiece.
top
§ 868.5630 Nebulizer.
top
§ 868.5640 Medicinal nonventilatory nebulizer (atomizer).
top
§ 868.5650 Esophageal obturator.
top
§ 868.5655 Portable liquid oxygen unit.
top
§ 868.5665 Powered percussor.
top
§ 868.5675 Rebreathing device.
top
§ 868.5690 Incentive spirometer.
top
§ 868.5700 Nonpowered oxygen tent.
top
§ 868.5710 Electrically powered oxygen tent.
top
§ 868.5720 Bronchial tube.
top
§ 868.5730 Tracheal tube.
top
§ 868.5740 Tracheal/bronchial differential ventilation tube.
top
§ 868.5750 Inflatable tracheal tube cuff.
top
§ 868.5760 Cuff spreader.
top
§ 868.5770 Tracheal tube fixation device.
top
§ 868.5780 Tube introduction forceps.
top
§ 868.5790 Tracheal tube stylet.
top
§ 868.5795 Tracheal tube cleaning brush.
top
§ 868.5800 Tracheostomy tube and tube cuff.
top
§ 868.5810 Airway connector.
top
§ 868.5820 Dental protector.
top
§ 868.5830 Autotransfusion apparatus.
top
§ 868.5860 Pressure tubing and accessories.
top
§ 868.5870 Nonrebreathing valve.
top
§ 868.5880 Anesthetic vaporizer.
top
§ 868.5895 Continuous ventilator.
top
§ 868.5905 Noncontinuous ventilator (IPPB).
top
§ 868.5915 Manual emergency ventilator.
top
§ 868.5925 Powered emergency ventilator.
top
§ 868.5935 External negative pressure ventilator.
top
§ 868.5955 Intermittent mandatory ventilation attachment.
top
§ 868.5965 Positive end expiratory pressure breathing attachment.
top
§ 868.5975 Ventilator tubing.
top
§ 868.5995 Tee drain (water trap).
top
Subpart G—Miscellaneous
top
§ 868.6100 Anesthetic cabinet, table, or tray.
top
§ 868.6175 Cardiopulmonary emergency cart.
top
§ 868.6225 Nose clip.
top
§ 868.6250 Portable air compressor.
top
§ 868.6400 Calibration gas.
top
§ 868.6700 Anesthesia stool.
top
§ 868.6810 Tracheobronchial suction catheter.
top
§ 868.6820 Patient position support.
top
§ 868.6885 Medical gas yoke assembly.
top