30 C.F.R. § 72.502   Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors.


Title 30 - Mineral Resources


Title 30: Mineral Resources
PART 72—HEALTH STANDARDS FOR COAL MINES
Subpart D—Diesel Particulate Matter—Underground Areas of Underground Coal Mines

Browse Previous |  Browse Next

§ 72.502   Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors.

(a) Each piece of nonpermissible light-duty diesel-powered equipment (as defined by §75.1908(b) of this chapter), other than generators and compressors, introduced into an underground area of an underground coal mine after May 21, 2001 must emit no more than 5.0 grams per hour of diesel particulate matter.

(b) A piece of nonpermissible light-duty diesel-powered equipment must be deemed to be in compliance with the requirements of paragraph (a) of this section if it utilizes an engine which meets or exceeds the applicable particulate matter emission requirements of the Environmental Protection Administration listed in Table 72.502–1, as follows:

                             Table 72.502-1------------------------------------------------------------------------       EPA requirement            EPA category            PM limit------------------------------------------------------------------------40 CFR 86.094-                light duty vehicle..  0.1 g/mile. 8(a)(1)(I)(A)(2).40 CFR 86.094-                light duty truck....  0.1 g/mile. 9(a)(1)(I)(A)(2).40 CFR 86.094-                heavy duty highway    0.1 g/bhp-hr. 11(a)(1)(iv)(B).              engine.40 CFR 89.112(a)............  Tier 2 nonroad......  Varies by power:                              kW< (hp<11)...  0.80 g/kW-hr (0.60 g/                                                     bhp-hr).                              8[le]kW<19         0.80 g/kW-hr (0.60 g/                               (11[le]hp<25).     bhp-hr).                              19[le]kW<37        0.60 g/kW-hr (0.45 g/                               (25[le]hp<50).     bhp-hr).                              37[le]kW<75        0.40 g/kW-hr (0.30 g/                               (50[le]hp<100).    bhp-hr).                              75[le]kW<130       0.30 g/kW-hr (0.22 g/                               (100[le]hp<175).   bhp-hr).                              130[le]kW<225      0.20 g/kW-hr (0.15 g/                               (175[le]hp<300).   bhp-hr).                              225[le]kW<450      0.20 g/kW-hr (0.15 g/                               (300[le]hp<600).   bhp-hr).                              450[le]kW<560      0.20 g/kW-hr (0.15 g/                               (600[le]hp<750)'   bhp-hr)                               '.                              kW>=560 (hp>=750)...  0.20 g/kW-hr (0.15 g/                                                     bhp-hr)------------------------------------------------------------------------ Notes: ``g'' means grams; ``kW'' means kilowatt; ``hp'' means  horsepower; ``g/kW-hr'' means grams/kilowatt-hour; ``g/bhp-hr'' means  grams/brake horsepower-hour.

(c) The requirements of this section do not apply to any diesel-powered ambulance or fire fighting equipment that is being used in accordance with the mine fire fighting and evacuation plan under §75.1502.

[66 FR 5704, Jan. 19, 2001, as amended at 66 FR 15033, Mar. 15, 2001; 66 FR 27866, May 21, 2001; 70 FR 36347, June 23, 2005]

Browse Previous |  Browse Next