30 C.F.R. § 27.34   Test for intrinsic safety.


Title 30 - Mineral Resources


Title 30: Mineral Resources
PART 27—METHANE-MONITORING SYSTEMS
Subpart C—Test Requirements

Browse Previous |  Browse Next

§ 27.34   Test for intrinsic safety.

Assemblies, subassemblies, or components that are designed for intrinsic safety shall be tested by introducing into the circuit(s) thereof a circuit-interrupting device which produces an electric spark from the current in the circuit. The circuit-interrupting device shall be placed in a gallery containing various flammable natural gas-air mixtures. To meet the requirements of this test, the spark shall not ignite the flammable mixture. For this test the circuit-interrupting device shall be operated not less than 100 times at 125 percent of the normal operating voltage of the particular circuit.