33 C.F.R. § 145.10   Locations and number of fire extinguishers required.


Title 33 - Navigation and Navigable Waters


Title 33: Navigation and Navigable Waters
PART 145—FIRE-FIGHTING EQUIPMENT

Browse Previous

§ 145.10   Locations and number of fire extinguishers required.

(a) Approved portable and semi-portable extinguishers shall be installed in accordance with Table 145.10(a).

(b) Semi-portable extinguishers shall be located in the open so as to be readily seen.

                            Table 145.10(a)_Portable and Semi-Portable Extinguishers----------------------------------------------------------------------------------------------------------------                  Space                           Classification                  Quantity and location----------------------------------------------------------------------------------------------------------------               safety areasCommunicating corridors..................  A-II........................  1 in each main corridor not more than                                                                          150 feet apart. (May be located in                                                                          stairways.)Radio room...............................  C-II........................  1 in vicinity of exit.              accommodationsSleeping accommodations..................  A-II........................  1 in each sleeping accommodation space.                                                                          (Where occupied by more than 4                                                                          persons.)             services spacesGalleys..................................  B-II or C-II................  1 for each 2,500 square feet or                                                                          fraction thereof for hazards involved.Storerooms...............................  A-II........................  1 for each 2,500 square feet or                                                                          fraction thereof located in vicinity                                                                          of exits, either inside or outside of                                                                          spaces.             machinery spacesGas-fired boilers........................  B-II (CO2 or dry chemical)..  2 required.Gas-fired boilers........................  B-V.........................  1 required.\1\Oil-fired boilers........................  B-II........................  2 required.Oil-fired boilers........................  B-V.........................  2 required.\1\Internal combustion or gas turbine         B-II........................  1 for each engine.\2\ engines.Electric motors or generators of open      C-II........................  1 for each 2 motors or generators.\3\ type.----------------------------------------------------------------------------------------------------------------\1\ Not required where a fixed carbon dioxide system is installed.\2\ When installation is on weather deck or open to atmosphere at all times 1 B-II for each three engines is  allowable.\3\ Small electrical appliances, such as fans, etc., shall not be counted or used as basis for determining  number of extinguishers required.

[CGFR 56–4, 21 FR 903, Feb. 9, 1956]

Browse Previous


chanrobles.com