33 C.F.R. § 159.103   Vibration test.


Title 33 - Navigation and Navigable Waters


Title 33: Navigation and Navigable Waters
PART 159—MARINE SANITATION DEVICES
Subpart C—Design, Construction, and Testing

Browse Previous |  Browse Next

§ 159.103   Vibration test.

The device, with liquid retention components, if any, filled with water to one-half of their volume, must be subjected to a sinusoidal vibration for a period of 12 hours, 4 hours in each of the x, y, and z planes, at the resonant frequency of the device (or at 55 cycles per second if there is no resonant frequency between 10 to 60 hertz) and with a peak amplitude of 0.019 to 0.021 inches.