33 C.F.R. § 159.111   Pressure and vacuum pulse test.


Title 33 - Navigation and Navigable Waters


Title 33: Navigation and Navigable Waters
PART 159—MARINE SANITATION DEVICES
Subpart C—Design, Construction, and Testing

Browse Previous |  Browse Next

§ 159.111   Pressure and vacuum pulse test.

Liquid retention components of the device with manufacturer specified venting installed must be subjected to 50 fillings of water at a pressure head of 7 feet or the maximum pressure specified by the manufacturer for operation of the device, whichever is greater, and then emptied with a 45 gallon per minute or larger positive displacement pump that remains in operation 30 seconds after emptying the tank at the end of each cycle.

Browse Previous |  Browse Next