33 C.F.R. § 159.123   Coliform test: Type I devices.


Title 33 - Navigation and Navigable Waters


Title 33: Navigation and Navigable Waters
PART 159—MARINE SANITATION DEVICES
Subpart C—Design, Construction, and Testing

Browse Previous |  Browse Next

§ 159.123   Coliform test: Type I devices.

(a) The arithmetic mean of the fecal coliform bacteria in 38 of 40 samples of effluent discharged from a Type I device during the test described in §159.121 must be less than 1000 per 100 milliliters when tested in accordance with 40 CFR Part 136.

(b) The 40 samples must be taken from the device as follows: During each of the 10-test days, one sample must be taken at the beginning, middle, and end of an 8-consecutive hour period with one additional sample taken immediately following the peak capacity processing period.

[CGD 73–83, 40 FR 4624, Jan. 30, 1975, as amended by CGD 75–213, 41 FR 15326, Apr. 12, 1976]