42 C.F.R. Table to Subpart J of Part 84


Title 42 - Public Health


Title 42: Public Health
PART 84—APPROVAL OF RESPIRATORY PROTECTIVE DEVICES
Subpart J—Supplied-Air Respirators


Table to Subpart J of Part 84
                                 Table 8_Air-Supply-Line Requirements and Tests                                           [42 CFR part 84, subpart J]----------------------------------------------------------------------------------------------------------------                                     Requirements for the air-supply lines of the indicated type of supplied-air                                                                     respirators       Specific requirements        ----------------------------------------------------------------------------                                             Type A                  Type B                     Type C----------------------------------------------------------------------------------------------------------------Length of hose.....................  Maximum of 91 m. (300   Maximum of 23 m. (75    Maximum of 91 m. (300 feet)                                      feet), in multiples     feet) in multiples of   in multiples of 7.6 m. (25                                      of 7.6 m. (25 feet).    7.6 m. (25 feet).       feet). It will be                                                                                      permissible for the                                                                                      applicant to supply hose                                                                                      of the approved type of                                                                                      shorter length than 7.6 m.                                                                                      (25 feet) provided it                                                                                      meets the requirements of                                                                                      the part.Air flow...........................  None..................  None..................  The air-supply hose with                                                                                      air regulating valve or                                                                                      orifice shall permit a                                                                                      flow of not less than 115                                                                                      liters (4 cubic feet) per                                                                                      minute to tight-fitting                                                                                      and 170 liters (6 cubic                                                                                      feet) per minute to loose-                                                                                      fitting respiratory-inlet                                                                                      coverings through the                                                                                      maximum length of hose for                                                                                      which approval is granted                                                                                      and at the minimum                                                                                      specified air-supply                                                                                      pressure. The maximum flow                                                                                      shall not exceed 425                                                                                      liters (15 cubic feet) per                                                                                      minute at the maximum                                                                                      specified air-supply                                                                                      pressure with the minimum                                                                                      length of hose for which                                                                                      approval is granted.Air flow...........................  ......do..............  ......do..............  The air-supply hose,                                                                                      detachable coupling, and                                                                                      demand valve of the demand                                                                                      class or pressure-demand                                                                                      valve of the pressure-                                                                                      demand class for Type C                                                                                      supplied-air respirators,                                                                                      demand and pressure-demand                                                                                      classes, shall be capable                                                                                      of delivering respirable                                                                                      air at a rate of not less                                                                                      than 115 liters (4 cubic                                                                                      feet) per minute to the                                                                                      respiratory-inlet covering                                                                                      at an inhalation                                                                                      resistance not exceeding                                                                                      50 millimeters (2 inches)                                                                                      of water-column height                                                                                      measured in the                                                                                      respiratory-inlet covering                                                                                      with any combination of                                                                                      air-supply pressure and                                                                                      length of hose within the                                                                                      applicant's specified                                                                                      range of pressure and hose                                                                                      length. The air-flow rate                                                                                      and resistance to                                                                                      inhalation shall be                                                                                      measured while the demand                                                                                      or pressure-demand valve                                                                                      is actuated 20 times per                                                                                      minute by a source of                                                                                      intermittent suction. The                                                                                      maximum rate of flow to                                                                                      the respiratory-inlet                                                                                      covering shall not exceed                                                                                      425 liters (15 cubic feet)                                                                                      per minute under the                                                                                      specified operating                                                                                      conditions.Air-regulating valve...............  ......do..............  ......do..............  If an air-regulating valve                                                                                      is provided, it shall be                                                                                      so designed that it will                                                                                      remain at a specific                                                                                      adjustment, which will not                                                                                      be affected by the                                                                                      ordinary movement of the                                                                                      wearer. The valve must be                                                                                      so constructed that the                                                                                      air supply with the                                                                                      maximum length of hose and                                                                                      at the minimum specified                                                                                      air-supply pressure will                                                                                      not be less than 115                                                                                      liters (4 cubic feet) of                                                                                      air per minute to tight-                                                                                      fitting and 170 liters (6                                                                                      cubic feet) of air per                                                                                      minute of loose-fitting                                                                                      respiratory inlet                                                                                      coverings for any                                                                                      adjustment of the valve.                                                                                      If a demand or pressure-                                                                                      demand valve replaces the                                                                                      air-regulating valve, it                                                                                      shall be connected to the                                                                                      air-supply at the maximum                                                                                      air pressure for which                                                                                      approval is sought by                                                                                      means of the minimum                                                                                      length of air-supply hose                                                                                      for which approval is                                                                                      sought. The outlet of the                                                                                      demand or pressure-demand                                                                                      valve shall be connected                                                                                      to a source of                                                                                      intermittent suction so                                                                                      that the demand or                                                                                      pressure-demand valve is                                                                                      actuated approximately 20                                                                                      times per minute for a                                                                                      total of 100,000                                                                                      inhalations. To expedite                                                                                      this test, the rate of                                                                                      actuation may be increased                                                                                      if mutually agreeable to                                                                                      the applicant and NIOSH.                                                                                      During this test the valve                                                                                      shall function without                                                                                      failure and without                                                                                      excessive wear of the                                                                                      moving parts. The demand                                                                                      or pressure-demand valve                                                                                      shall not be damaged in                                                                                      any way when subjected at                                                                                      the outlet to a pressure                                                                                      or suction of 25 cm. (10                                                                                      inches) of water gage for                                                                                      2 minutes.Noncollapsibility..................  The hose shall not      Same as Type A........  None.                                      collapse or exhibit                                      permanent deformation                                      when a force of 90                                      kg. (200 pounds) is                                      applied for 5 minutes                                      between 2 planes 7.6                                      cm. (3 inches) wide                                      on opposite sides of                                      the hose.Nonkinkability.....................  None..................  None..................  A 7.6 m. (25 foot) section                                                                                      of the hose will be placed                                                                                      on a horizontal-plane                                                                                      surface and shaped into a                                                                                      one-loop coil with one end                                                                                      of the hose connected to                                                                                      an airflow meter and the                                                                                      other end of the hose                                                                                      supplied with air at the                                                                                      minimum specified supply                                                                                      pressure. The connection                                                                                      shall be in the plane of                                                                                      the loop. The other end of                                                                                      the hose will be pulled                                                                                      tangentially to the loop                                                                                      and in the plane of the                                                                                      loop until the hose                                                                                      straightens. To meet the                                                                                      requirements of this test                                                                                      the loop shall maintain a                                                                                      uniform near-circular                                                                                      shape and ultimately                                                                                      unfold as a spiral,                                                                                      without any localized                                                                                      deformation that decreases                                                                                      the flow of air to less                                                                                      than 90 percent of the                                                                                      flow when the hose is                                                                                      tested while remaining in                                                                                      a straight line.Strength of hose and couplings.....  Hose and couplings      Same as Type A........  Hose and couplings shall                                      shall not separate or                           not exhibit any separation                                      fail when tested with                           or failure when tested                                      a pull of 113 kg.                               with a pull of 45 kg. (100                                      (250 pounds) for 5                              pounds) for 5 minutes and                                      minutes.                                        when tested by subjecting                                                                                      them to an internal air                                                                                      pressure of 2 times the                                                                                      maximum respirator-supply                                                                                      pressure that is specified                                                                                      by the applicant or at 173                                                                                      kN/m. 2 (25 pounds per                                                                                      square inch) gage,                                                                                      whichever is higher.Tightness..........................  No air leakage shall    None..................  Leakage of air exceeding 50                                      occur when the hose                             cc. per minute at each                                      and couplings are                               coupling shall not be                                      joined and the                                  permitted when the hose                                      joint(s) are immersed                           and couplings are joined                                      in water and                                    and are immersed in water,                                      subjected to an                                 with air flowing through                                      internal air pressure                           the respirator under a                                      of 35 kN/m. 2 (5                                pressure of 173 kN/m. 2                                      pounds per square                               (25 pounds per square                                      inch) gage.                                     inch) gage applied to the                                                                                      inlet end of the air-                                                                                      supply hose, or at twice                                                                                      the maximum respirator-                                                                                      supply pressure that is                                                                                      specified by the                                                                                      applicant, whichever is                                                                                      higher.Permeation of hose by gasoline.....  The permeation of the   Same as for Type A....  Same as for Type A, except                                      hose by gasoline will                           the test period shall be 1                                      be tested by                                    hour.                                      immersing 7.6 m. (25                                      feet) of hose and one                                      coupling in gasoline,                                      with air flowing                                      through the hose at                                      the rate of 8 liters                                      per minute for 6                                      hours. The air from                                      the hose shall not                                      contain more than                                      0.01 percent by                                      volume of gasoline                                      vapor at the end of                                      the test.Detachable coupling................  None..................  None..................  A hand-operated detachable                                                                                      coupling by which the                                                                                      wearer can readily attach                                                                                      or detach the connecting                                                                                      hose shall be provided at                                                                                      a convenient location.                                                                                      This coupling shall be                                                                                      durable, remain connected                                                                                      under all conditions of                                                                                      normal respirator use, and                                                                                      meet the prescribed tests                                                                                      for strength and tightness                                                                                      of hose and couplings.----------------------------------------------------------------------------------------------------------------





chanrobles.com