42 C.F.R. § 84.1149   Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.


Title 42 - Public Health


Title 42: Public Health
PART 84—APPROVAL OF RESPIRATORY PROTECTIVE DEVICES
Subpart KK—Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying High Efficiency Respirators and Combination Gas Masks

Browse Previous |  Browse Next

§ 84.1149   Airflow resistance tests; all dust, fume, and mist respirators; minimum requirements.

(a) Resistance to airflow will be measured in the facepiece, mouthpiece, hood, or helmet of a dust, fume, or mist respirator mounted on a test fixture with air flowing at a continuous rate of 85 liters per minute, both before and after each test conducted in accordance with §§84.1144 through 84.1147.

(b) The maximum allowable resistance requirements for dust, fume, and mist respirators are as follows:

                           Maximum Resistance                        [mm. water-column height]------------------------------------------------------------------------                                     Initial       Final        Type of respirator          inhalation   inhalation   Exhalation------------------------------------------------------------------------Pneumoconiosis- and fibrosis-               12           15           15 producing dusts, or dusts and mists...........................Dust, fume, and mist, with single-          30           50           20 use filter......................Dust, fume, and mist, with                  20           40           20 reusable filter.................Radon daughter...................           18       \1\ 25           15Asbestos dust and mist...........           18           25           15------------------------------------------------------------------------\1\ Measured after silica dust test described in § 84.1144.

Browse Previous |  Browse Next

chanrobles.com