42 C.F.R. Tables to Subpart KK of Part 84


Title 42 - Public Health


Title 42: Public Health
PART 84—APPROVAL OF RESPIRATORY PROTECTIVE DEVICES
Subpart KK—Dust, Fume, and Mist; Pesticide; Paint Spray; Powered Air-Purifying High Efficiency Respirators and Combination Gas Masks


Tables to Subpart KK of Part 84
                  Table 12_Facepiece Test Requirements                      [42 CFR Part 84, Subpart KK]------------------------------------------------------------------------                                  Pressure       Isoamyl acetate test       Respirator types           tightness  ---------------------------                                  test \1\       84.1141       84.1142------------------------------------------------------------------------Dusts: Air Contamination Level            X not less than 0.05 mg/M\3\ or 2 mppcf......................Fumes: Air Contamination Level            X             X not less than 0.05 mg/M\3\...Mists: Air Contamination Level            X not less than 0.05 mg/M\3\ or 2 mppcf......................Dusts, Fumes, and Mists: Air              X   ............            X Contamination Level less than 0.05 mg/M\3\ or 2 mppcf, and radionuclides................Radon daughters...............            X             XAsbestos-containing dusts and             X mists........................------------------------------------------------------------------------\1\ Test is required only where applicable.
         Table 13_Air-Purifying and Powered Air-Purifying Respirator Filter Tests Required for Approval                                          [42 CFR Part 84, Subpart KK]----------------------------------------------------------------------------------------------------------------                                          Silica dust tests      Respirator types       ------------------------------------------   Lead fume    Silica mist    DOP test                                 84.1144       84.1145       84.1152    test 84.1146  test 84.1147     84.1151----------------------------------------------------------------------------------------------------------------Dusts: Air Contamination                X Level not less than 0.05 mg/ M\3\ or 2 mppcf............Fumes: Air Contamination      ............  ............  ............            X Level not less than 0.05 mg/ M\3\.......................Mists: Air Contamination      ............  ............  ............  ............            X Level not less than 0.05 mg/ M\3\ or 2 mppcf............Dusts, Fumes, and Mists: Air  ............  ............            X   ............  ............            X Contamination Level less than 0.05 mg/M\3\ or 2 mppcf, and radionuclides...Radon daughters.............        \1\ X   ............  ............  ............        \2\ XAsbestos-containing dusts           \2\ X   ............  ............  ............        \3\ X and mists..................Single use dust and mist      ............        \3\ X   ............  ............        \3\ X respirators................----------------------------------------------------------------------------------------------------------------\1\ For resistance only.\2\ For penetration only.\3\ Test required only where applicable.
             Table 14_Carbon Tetrachloride Bench Tests and Requirements for Canisters and Cartridges                                          [42 CFR part 84, Subpart KK]----------------------------------------------------------------------------------------------------------------                                                                 Test                                  Minimum               Type of pesticide respirator                 concentration   Flow rate    Number of       life                                                             p.p.m. CCl4      l.p.m.       tests      minutes\1\----------------------------------------------------------------------------------------------------------------Chest-mounted or back-mounted gas mask (as received)......        20,000            64            3           12Chest-mounted or back-mounted gas mask (equilibrated).....        20,000            32            4           12Chin-style gas mask (as received).........................         5,000            64            3           12Chin-style gas mask (equilibrated)........................         5,000            32            4           12Chemical Cartridge respirator (as received)...............         1,000            64            3           50Chemical cartridge respirator (equilibrated)..............         1,000            32            4           50Powered air-purifying respirator (tight-fitting facepiece,         1,000       \2\ 115            3           50 as received).............................................Powered air-purifying respirator (tight-fitting facepiece,         1,000       \2\ 115            4           25 equilibrated)............................................Powered air-purifying respirator (loose-fitting hood or            1,000       \3\ 170            3           50 helmet, as received).....................................Powered air-purifying respirator (loose-fitting hood or            1,000       \3\ 170            4           25 helmet, equilibrated)....................................----------------------------------------------------------------------------------------------------------------\1\ Minimum life will be determined at 5 p.p.m. leakage.\2\ The flow rate shall be the effective flow rate of the device, but shall be not less than 115 l.p.m.\3\ The flow rate shall be the effective flow rate of the device, but shall be not less than 170 l.p.m.





chanrobles.com