46 C.F.R. § 25.30-20   Fire extinguishing equipment required.


Title 46 - Shipping


Title 46: Shipping
PART 25—REQUIREMENTS
Subpart 25.30—Fire Extinguishing Equipment

Browse Previous |  Browse Next

§ 25.30-20   Fire extinguishing equipment required.

(a) Motorboats. (1) All motorboats shall carry at least the minimum number of hand portable fire extinguishers set forth in Table 25.30–20(a)(1), except that motorboats less than 26 feet in length, propelled by outboard motors and not carrying passengers for hire, need not carry such portable fire extinguishers if the construction of such motorboats will not permit the entrapment of explosive or flammable gases or vapors.

                          Table 25.30-20(a)(1)------------------------------------------------------------------------                                             Minimum number of B-1 hand                                             portable fire extinguishers                                                    required \1\                                           -----------------------------               Length, feet                 No fixed fire    Fixed fire                                            extinguishing  extinguishing                                              system in      system in                                              machinery      machinery                                                space          space------------------------------------------------------------------------Under 16..................................           1              016 and over, but under 26.................           1              026 and over, but under 40.................           2              140 and over, but not over 65..............           3              2------------------------------------------------------------------------\1\ One B-11 hand portable fire extinguisher may be substituted for two  B-I hand portable fire extinguishers.

(2) The intent of this regulation is illustrated in Figure 25.30–20(a1) where fire extinguishers are required if any one or more of the specified conditions exist, and in Figure 25.30–20(a2) where specified conditions do not, in themselves, require that fire extinguishers be carried.

Figure 25.30–20(a1)

View or download PDF

Fire extinguishers are required if any one or more of the following conditions exist (numbers identifying conditions are the same as those placed in Figure 25.30–20 (a1)):

1. Closed compartment under thwarts and seats wherein portable fuel tanks may be stored.

2. Double bottoms not sealed to the hull or which are not completely filled with flotation material.

3. Close living spaces.

4. Closed stowage compartments in which combustible or flammable materials are stowed.

5. Permanently installed fuel tanks.

Figure 25.30–20(a2)

View or download PDF

The following conditions do not, in themselves, require that fire extinguishers be carried (numbers identifying conditions are the same as those placed in Figure 25.30–20(a2)):

1. Bait wells.

2. Glove compartments.

3. Buoyant flotation material.

4. Open slatted flooring.

5. Ice chests.

(b) Uninspected passenger vessels of at least 100 gross tons. All uninspected passenger vessels of at least 100 gross tons must carry onboard hand-portable and semi-portable fire extinguishers per Table 76.50–10(a) in §76.50–10 of this chapter.

(c) Motor vessels. (1) All motor vessels shall carry at least the minimum number of hand portable fire extinguishers set forth in Table 25.30–20(b) (1).

                          Table 25.30-20(b)(1)------------------------------------------------------------------------             Gross tonnage_----------------------------------------   Minimum number of B-II hand            Over               Not over    portable fire extinguishers------------------------------------------------------------------------                                     50                 150..........................        100                 2100.........................        500                 3500.........................      1,000                 61,000.......................  .........                 8------------------------------------------------------------------------

(2) In addition to the hand portable fire extinguishers required by paragraph (b)(1) of this section, the following fire-extinguishing equipment shall be fitted in the machinery space:

(i) One Type B-II hand portable fire extinguisher shall be carried for each 1,000 B. H. P. of the main engines or fraction thereof. However, not more than 6 such extinguishers need be carried.

(ii) On motor vessels of over 300 gross tons, either one Type B-III semiportable fire-extinguishing system shall be fitted, or alternatively, a fixed fire-extinguishing system shall be fitted in the machinery space.

(3) The frame or support of each Type B-III fire extinguisher required by paragraph (b)(2)(ii) of this section must be welded or otherwise permanently attached to a bulkhead or deck.

(4) If an approved semiportable fire extinguisher has wheels and is not required by this section, it must be securely stowed when not in use to prevent it from rolling out of control under heavy sea conditions.

(d) Barges carrying passengers. (1) Every barge of 65 feet in length or less while carrying passengers when towed or pushed by a motorboat, motor vessel, or steam vessel shall be fitted with hand portable fire extinguishers as required by Table 25.30–20(a)(1), depending upon the length of the barge.

(2) Every barge of over 65 feet in length while carrying passengers when towed or pushed by a motorboat, motor vessel, or steam vessel shall be fitted with hand portable fire extinguishers as required by Table 25.30–20(b)(1), depending upon the gross tonnage of the barge.