46 C.F.R. § 28.160 Portable fire extinguishers.
Title 46 - Shipping
(a) Each vessel must meet the requirements of part 25, subpart 25.30 of this chapter. (b) Each vessel 65 feet (19.8 meters) or more in length must be equipped with the minimum number, location, and type of portable fire extinguishers specified in table 28.160. [CGD 88–079, 56 FR 40393, Aug. 14, 1991; 56 FR 47679, Sept. 20, 1991]
Title 46: Shipping
PART 28—REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS
Subpart B—Requirements for All Vessels
§ 28.160 Portable fire extinguishers.
Table 28.160_Portable Fire Extinguishers for Vessels 65 Feet (19.8 Meters) or More in Length------------------------------------------------------------------------ Space Classification Quantity and location------------------------------------------------------------------------Safety areas, communicating A-II............. 1 in each main corridors. corridor not more than 150 feet (49.2 meters) apart. (May be located in stairways.)Pilothouse.................... C-I.............. 2 in vicinity of exit.Service spaces, galleys....... B-II or C-II..... 1 for each 2,500 square feet (269.1 sq. meters) or fraction thereof suitable for hazards involved.Paint lockers................. B-II............. 1 outside space in vicinity of exit.Accessible baggage and A-II............. 1 for each 2,500 storerooms. square feet (269.1 sq. meters) or fraction thereof located in the vicinity of exits, either inside or outside the spaces.Work shops and similar spaces. A-II............. 1 outside the space in vicinity of exit.Machinery spaces; Internal B-II............. 1 for each 1,000 combustion propelling brake horsepower or machinery. fraction thereof but not less than 2 nor more than 6.Electric propulsion motors or C-II............. 1 for each propulsion generator unit of open type. motor generator unit.Auxiliary spaces.............. B-II............. 1 outside the space in the vicinity of exit.Internal combustion machinery. B-II............. 1 outside the space in the vicinity of exit.Electric emergency motors or C-II............. 1 outside the space generators. in the vicinity of exit.------------------------------------------------------------------------