46 C.F.R. § 28.355   Main source of electrical power.


Title 46 - Shipping


Title 46: Shipping
PART 28—REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS
Subpart D—Requirements for Vessels Which Have Their Keel Laid or Are at a Similar Stage of Construction on or After or Which Undergo a Major Conversion Completed on or After September 15, 1991, and That Operate With More Than 16 Individuals on Board

Browse Previous |  Browse Next

§ 28.355   Main source of electrical power.

(a) Applicability. Each vessel that relies on electricity to power any of the following essential loads must have at least two electrical generators to supply these loads:

(1) The propulsion system and its necessary auxiliaries and controls;

(2) Interior lighting;

(3) Steering systems;

(4) Communication systems;

(5) Navigation equipment and navigation lights;

(6) Fire protection or detection equipment;

(7) Bilge pumps; or

(8) General alarm system.

(b) Each generator must be attached to an independent prime mover.

Browse Previous |  Browse Next