46 C.F.R. § 42.15-35 Machinery space openings.
Title 46 - Shipping
(a) Machinery space openings in position 1 or 2 shall be properly framed and efficiently enclosed by steel casings of ample strength, and where the casings are not protected by other structures their strength shall be specifically considered. Access openings in such casings shall be fitted with doors complying with the requirements of §42.15–10(a), the sills of which shall be at least 23 (b) Coamings of any fiddley, funnel, or machinery space ventilators in an exposed position on the freeboard or superstructure deck shall be as high above the deck as is reasonable and practicable. Fiddley openings shall be fitted with strong covers of steel or other equivalent material permanently attached in their proper positions and capable of being secured weathertight. [CGFR 68–60, 33 FR 10061, July 12, 1968]
Title 46: Shipping
PART 42—DOMESTIC AND FOREIGN VOYAGES BY SEA
Subpart 42.15—Conditions of Assignment of Freeboard
§ 42.15-35 Machinery space openings.