46 C.F.R. § 45.61   Correction for superstructures and trunks.


Title 46 - Shipping


Title 46: Shipping
PART 45—GREAT LAKES LOAD LINES
Subpart C—Freeboards

Browse Previous |  Browse Next

§ 45.61   Correction for superstructures and trunks.

(a) Where the effective length E of superstructures and trunks that meet the requirements of subpart D of this part is 1.0L, the minimum summer freeboard may be corrected by subtracting 1/2Hs.

(b) Where the effective length of superstructures and trunks is less than 1.0L the minimum summer freeboard may be corrected by subtracting a percentage of one-half of the standard superstructure height (Hs) determined by the formula:

Percentage=(E/2L) (1+E/L)×100

(c) To be eligible for the correction a trunk must—

(1) Be at least as strong and as stiff as a superstructure;

(2) Have no opening in the freeboard deck in way of the trunk, except small access openings;

(3) Have hatchway coamings and covers that meet §§45.143 through 45.147;

(4) Provide a permanent working platform fore and aft with guardrails;

(5) Provide fore and aft access between detached trunks and superstructures by permanent gangways;

(6) Be at least 60 percent of the breadth of the ship in way of the trunk; and

(7) Be at least 0.6 L in length, if no superstructure, is provided.