46 C.F.R. § 56.50-45   Circulating pumps.


Title 46 - Shipping


Title 46: Shipping
PART 56—PIPING SYSTEMS AND APPURTENANCES
Subpart 56.50—Design Requirements Pertaining to Specific Systems

Browse Previous |  Browse Next

§ 56.50-45   Circulating pumps.

(a) A main circulating pump and emergency means for circulating water through the main condenser shall be provided. The emergency means may consist of a connection from an independent power pump fitted between the main circulating pump and the condenser.

(b) Independent sea suctions shall be provided for the main circulating and the emergency circulating pumps.

(c) A cross connection between the circulating pumps in the case of multiple units will be acceptable in lieu of an independent power pump connection.

(d) On vessels operating on lakes (including Great Lakes), bays, sounds, or rivers, where provision is made to operate noncondensing, only one circulating unit will be required.