46 C.F.R. Subpart E—Emergency Signals
Title 46 - Shipping
(a) Emergency stations signals are established as follows: (1) The signal to man emergency stations is a rapid succession of short soundings of both the general alarm bell and the whistle, if a whistle is installed, for a period of not less than 10 seconds. (2) The signal to secure from emergency stations is the sounding of both the general alarm bell and the whistle, if a whistle is installed, three times. (b) The abandon unit stations signals are established as follows: (1) The signal to man abandon unit stations is a continuous sounding of both the general alarm and the whistle, if a whistle is installed. (2) If whistle signals are used to direct the handling of lifeboats and davit-launched liferafts, they must be— (i) One short blast to lower the lifeboats and davit-launched liferafts; and (ii) Two short blasts to stop lowering the lifeboats and davit-launched liferafts. (3) The signal to secure from abandon unit stations is the sounding of both the general alarm bell and the whistle, if a whistle is installed, three times. [CGD 73–251, 43 FR 56828, Dec. 4, 1978, as amended by CGD 84–069, 61 FR 25303, May 20, 1996]
Title 46: Shipping
PART 109—OPERATIONS
Subpart E—Emergency Signals
§ 109.503 Emergency signals.