§ 111.60-13   Flexible electric cord and cables.

(a) Construction and testing. Each flexible cord and cable must meet the requirements in section 19.6.1 of IEEE Std 45, article 400 of the NEC, NEMA WC 3, NEMA WC 8, or UL 62.

(b) Application. A flexible cord must be used:

(1) Only as allowed under Sections 400–7 and 400–8 of the National Electrical Code; and

(2) In accordance with Table 400–4 of the National Electrical Code.

(c) Allowable current-carrying capacity. A flexible cord must not carry more current than allowed under Table 400–5 of the National Electrical Code, NEMA WC 3 or NEMA WC 8.

(d) Conductor size. Each flexible cord must be No. 18 AWG (0.82 mm2 ) or larger.

(e) Splices. Each flexible cord and cable must be without splices or taps except for a cord or cable No. 12 AWG (3.3 mm2 ) or larger spliced for repairs in accordance with §111.60–19.

(f) Pull at joints and terminals. Each flexible cord and cable must be connected to a device or fitting by a knot, tape, or special fitting so that tension is not transmitted to joints or terminal screws.

[CGD 74–125A, 47 FR 15236, Apr. 8, 1982, as amended by CGD 94–108, 61 FR 28281, June 4, 1996]