46 C.F.R. § 111.60-4   Minimum cable conductor size.


Title 46 - Shipping


Title 46: Shipping
PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS
Subpart 111.60—Wiring Materials and Methods

Browse Previous |  Browse Next

§ 111.60-4   Minimum cable conductor size.

Each cable conductor must be #18 AWG (0.82 mm2 ) or larger except—

(a) Each power and lighting cable conductor must be #14 AWG (2.10 mm2 ) or larger; and

(b) Each thermocouple, pyrometer, or instrumentation cable conductor must be #22 AWG (0.33 mm2 ) or larger.

[CGD 94–108, 61 FR 28280, June 4, 1996]