46 C.F.R. § 117.150 Survival craft embarkation arrangements.
Title 46 - Shipping
(a) A launching appliance approved under approval series 160.163 or a marine evacuation system approved under approval series 160.175 must be provided for each inflatable liferaft and inflatable buoyant apparatus when either— (1) The embarkation station for the survival craft is on a deck more than 4.5 meters (15 feet) above the waterline; or (2) The inflatable liferaft or inflatable buoyant apparatus will be boarded prior to being placed in the water. (b) An embarkation ladder, approved in accordance with §160.017 in subchapter Q of this chapter, or other standard specified by the Commandant, must be at each embarkation station if the distance from the embarkation deck to the vessel's lightest operating waterline is more than 3,050 millimeters (10 feet). [CGD 85–080, 61 FR 911, Jan. 10, 1996, as amended at 62 FR 51350, Sept. 30, 1997; 62 FR 64305, Dec. 5, 1997]
Title 46: Shipping
PART 117—LIFESAVING EQUIPMENT AND ARRANGEMENTS
Subpart D—Survival Craft Arrangements and Equipment
§ 117.150 Survival craft embarkation arrangements.