46 C.F.R. § 119.470 Ventilation of spaces containing diesel fuel tanks.
Title 46 - Shipping
(a) Unless provided with ventilation that complies with §119.465 of this part, a space containing a diesel fuel tank and no machinery must meet one of the following requirements: (1) A space of 14 cubic meters (500 cubic feet) or more in volume must have a gooseneck vent of not less than 65 millimeters (2.5 inches) in diameter; or (2) A space of less than 14 cubic meters (500 cubic feet) in volume must have a gooseneck vent of not less than 40 millimeters (1.5 inches) in diameter. (b) Vent openings may not be located adjacent to possible sources of vapor ignition.
Title 46: Shipping
PART 119—MACHINERY INSTALLATION
Subpart D—Specific Machinery Requirements
§ 119.470 Ventilation of spaces containing diesel fuel tanks.