46 C.F.R. § 153.351 Location of 4m vent discharges.
Title 46 - Shipping
Except as prescribed in §153.353, a 4m venting system must discharge: (a) At least 4m (approx. 13.1 ft) above the higher of: (1) the weatherdeck; or (2) any walkway that is within a 4m (approx. 13.1 ft) horizontal radius from the vent discharge. (b) At least 10m (approx. 32.8 ft) from air intakes for, or openings into, accommodation or service spaces. [CGD 78–128, 47 FR 21208, May 17, 1982]
Title 46: Shipping
PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS
Subpart B—Design and Equipment
Cargo Venting Systems
§ 153.351 Location of 4m vent discharges.