§ 169.559   Fire pumps.

(a) Each sailing school vessel must be equipped with fire pumps as required in Table 169.559(a).

                       Table 169.559(a)_Fire Pumps------------------------------------------------------------------------                                                Exposed and                                                 partially    Protected                    Length                       protected      water                                                   water       service                                                  service------------------------------------------------------------------------65 feet but less than 90 feet.................        \1\ 1            090 feet but less than 120 feet................        \2\ 1        \1\ 1120 feet or greater...........................        \3\ 2        \1\ 1------------------------------------------------------------------------\1\ May be driven off a propulsion engine and may be used as a bilge  pump.\2\ Must be driven by a source of power independent of the propulsion  engine and may be used as a bilge pump.\3\ One pump may be driven off a propulsion unit and one pump may be  used as a bilge pump. Pumps must be located in separate spaces.

(b) Fire pump capacity must be in accordance with the following:

 ------------------------------------------------------------------------            Vessel length                      Minimum capacity------------------------------------------------------------------------Less than 90 ft.....................  5.5 m\3\/hr (25 gpm).90 feet but less than 120 ft........  11.0 m\3\/hr (50 gpm).Greater than 120 ft.................  14.3 m\3\/hr (66.6 gpm).------------------------------------------------------------------------

(c) Each fire pump must be fitted with a pressure gage on the discharge side of the pump.

(d) Each vessel must have a hand operated portable fire pump having a capacity of at least 1.1 m3 /hr (5 gpm). This pump must be equipped with suction and discharge hose suitable for use in firefighting.