46 C.F.R. § 169.608   Non-integral keel cooler installations


Title 46 - Shipping


Title 46: Shipping
PART 169—SAILING SCHOOL VESSELS
Subpart 169.600—Machinery and Electrical
Internal Combustion Engine Installations

Browse Previous |  Browse Next

§ 169.608   Non-integral keel cooler installations

(a) Hull penetrations for non-integral keel cooler installations must be made through a cofferdam or at a sea chest.

(b) Non-integral keel coolers must be suitably protected against damage from debris and grounding by recessing the unit into the hull or by the placement of protective guards.

(c) Each non-integral keel cooler hull penetration must be equipped with a shutoff valve.

[CGD 83–005, 51 FR 896, Jan. 9, 1986, as amended by USCG–2000–7790, 65 FR 58464, Sept. 29, 2000]