46 C.F.R. § 171.073 Treatment of stepped and recessed bulkheads in Type II subdivision.
Title 46 - Shipping
(a) A main transverse watertight bulkhead may not be stepped unless additional watertight bulkheads are located as shown in Figure 171.067(a) so that the distances A, B, C, and D illustrated in Figure 171.067(a) comply with the following: (1) A and B must not exceed the maximum bulkhead spacing that permits compliance with §171.070; and (2) C and D must not be less than the minimum spacing specified in §171.070(e). (b) A main transverse watertight bulkhead may not be recessed unless all parts of the recess are inboard from the shell of the vessel as illustrated in Figure 171.067(c). (c) If a main transverse watertight bulkhead is recessed or stepped, an equivalent plane bulkhead must be used in the calculations required by §171.070.
Title 46: Shipping
PART 171—SPECIAL RULES PERTAINING TO VESSELS CARRYING PASSENGERS
Subpart C—Large Vessels
§ 171.073 Treatment of stepped and recessed bulkheads in Type II subdivision.