46 C.F.R. § 181.500   Required number, type, and location.


Title 46 - Shipping


Title 46: Shipping
PART 181—FIRE PROTECTION EQUIPMENT
Subpart E—Portable Fire Extinguishers

Browse Next

§ 181.500   Required number, type, and location.

(a) Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by Table 181.500(a) and other provisions of this section.

                                                Table 181.500(a)----------------------------------------------------------------------------------------------------------------                                                                  Type extinguisher permitted       Space protected          Minimum No.   ------------------------------------------------------------------                                  required         CG class               Medium                  Min size----------------------------------------------------------------------------------------------------------------Operating Station...........  1..............  B-I, C-I.......  Halon....................  1.1 kg (2.5 lb).                                                                CO2......................  1.8kg (4 lb).                                                                Dry Chemical.............  0.9 kg (2 lb).Machinery Space.............  1..............  B-II, C-II       CO2......................  6.8 kg (15 lb).                                                located just                                                outside exit.                                                                Dry chemical.............  4.5 kg (10 lb).Open Vehicle Deck...........  1 for every 10   B-II...........  Foam.....................  9.5 L (2.5 gal).                               vehicles.                                                                Halon....................  4.5 kg (10 lb).                                                                CO2......................  6.8 kg (15 lb).                                                                Dry Chemical.............  4.5 kg (10 lb).Accomodation Space..........  1 for each       A-II...........  Foam.....................  9.5 L (2.5 gal).                               232.3 square                     Dry Chemical.............  4.5 kg (10 lb).                               meters (2,500                               square feet)                               or fraction                               thereof.Galley, Pantry, Concession    1..............  A-II, B-II.....  Foam.....................  9.5 L (2.5 gal). Stand.                                                                Dry Chemical.............  4.5 kg (10 lb).----------------------------------------------------------------------------------------------------------------

(b) A vehicle deck without a fixed sprinkler system and exposed to weather must have one B-II portable fire extinguisher for every five vehicles, located near an entrance to the space.

(c) The cognizant OCMI may permit the use of a larger portable fire extinguisher, or a semiportable fire extinguisher, in lieu of those required by this section.

(d) The frame or support of each B-V fire extinguisher permitted by paragraph (c) of this section must be welded or otherwise permanently attached to a bulkhead or deck.

[CGD 85–080, 61 FR 982, Jan. 10, 1996; 61 FR 24464, May 15, 1996, as amended at 62 FR 51358, Sept. 30, 1997]

Browse Next

chanrobles.com