49 C.F.R. 49 CFR--PART 173
Title 49 - Transportation
Effective Date(s): September 11, 2006 19. In §173.195, paragraph (a) is revised to read as follows: (a) Hydrogen cyanide, anhydrous, stabilized, must be packed in specification cylinders or UN pressure receptacles as follows: (1) As prescribed in §173.192; (2) Specification 3A480, 3A480X, 3AA480, or 3A1800 metal cylinders of not over 126 kg (278 pounds) water capacity (nominal); (3) Shipments in 3AL cylinders are authorized only when transported by highway and rail; or (4) UN cylinders, as specified in part 178, with a minimum test pressure of 100 bar and a maximum filling ratio of 0.55. The use of UN tubes and MEGCs is not authorized. * * * * *
Amendment from June 12, 2006
49 CFR--PART 173
Amendment(s) published June 12, 2006, in 71 FR 33880
§ 173.195 Hydrogen cyanide, anhydrous, stabilized (hydrocyanic acid, aqueous solution).