§ 179.401-1   Individual specification requirements.

In addition to §179.400, the individual specification requirements for the inner tank and its appurtenances are as follows:

 ------------------------------------------------------------------------        DOT specification               113A60W            113C120W------------------------------------------------------------------------Design service temperature,       -423..............  -260. °F.Material........................  § 179.400-5..  § 179.400-5.Impact test (weld and plate       § 179.400-     § 179.400- material).                        5(c).               5(c).Impact test values..............  § 179.400-     § 179.400-                                   5(d).               5(d).Standard heat transfer rate.  (Btu per day per lb. of water   0.097.............  0.4121.   capacity, max.) (see §   179.400-4).Bursting pressure, min. psig....  240...............  300.Minimum plate thickness shell,    \3/16\............  \3/16\. inches (see § 179.400- 7(a)).Minimum head thickness, inches    \3/16\............  \3/16\. (see § 179.400-8 (a), (b), and (c)).Test pressure, psig (see §   60................  120. 179.400-16).Safety vent bursting pressure,    60................  120. max. psig.Pressure relief valve start-to-   30................  75. discharge pressure, psig (±3 psi).Pressure relief valve vapor       24................  60. tight pressure, min. psig.Pressure relief valve flow        40................  85. rating pressure, max. psig.Alternate pressure relief valve   ..................  90. start to-discharge pressure, psig (±3 psi).Alternate pressure relief valve   ..................  72. vapor tight pressure, min. psig.Alternate pressure relief valve   ..................  100. flow rating pressure, max. psig.Pressure control valve Start-to-  17................  Not required. vent, max. psig (see § 179.400-20(c)(4)).Relief device discharge           § 179.400-20.  179.400-20. restrictions.Transfer line insulation........  § 179.400-17.  Not required.------------------------------------------------------------------------

[Amdt. 179–32, 48 FR 27708, June 16, 1983, as amended at 49 FR 24318, June 12, 1984; 65 FR 58632, Sept. 29, 2000; 66 FR 45390, Aug. 28, 2001]

Browse Previous |  Browse Next

chanrobles.com