10 C.F.R. § 431.106   Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters).


Title 10 - Energy


Title 10: Energy
PART 431—ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT
Subpart G—Commercial Water Heaters, Hot Water Supply Boilers and Unfired Hot Water Storage Tanks
Test Procedures

Browse Previous |  Browse Next

§ 431.106   Uniform test method for the measurement of energy efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water heaters).

(a) Scope. This section covers the test procedures you must follow if, pursuant to EPCA, you are measuring the thermal efficiency or standby loss, or both, of a storage or instantaneous water heater or hot water supply boiler (other than a commercial heat pump water heater).

(b) Testing and Calculations. Determine the energy efficiency of each covered product by conducting the test procedure(s), set forth in the two rightmost columns of the following table, that apply to the energy efficiency descriptor(s) for that product:

 ----------------------------------------------------------------------------------------------------------------                                                                 Use test setup,                                                                  equipment and              Product                   Energy efficiency         procedures in         With these additional                                           descriptor          subsection labeled            stipulations                                                              ``Method of Test'' of----------------------------------------------------------------------------------------------------------------Gas-fired Storage and Instantaneous  Thermal Efficiency....  ANSI Z21.10.3-1998,     A. For all products, the Water Heaters and Hot Water Supply                           § 2.9**.           duration of the standby Boilers*.                                                                            loss test shall be until                                                                                      whichever of the following                                                                                      occurs first after you                                                                                      begin to measure the fuel                                                                                      and/or electric                                                                                      consumption: (1) The first                                                                                      cutout after 24 hours or                                                                                      (2) 48 hours, if the water                                                                                      heater is not in the                                                                                      heating mode at that time.                                     Standby Loss..........  ANSI Z21.10.3-1998,     B. For oil and gas                                                              § 2.10**.          products, the standby loss                                                                                      in Btu per hour must be                                                                                      calculated as follows: SL                                                                                      (Btu per hour) = S (% per                                                                                      hour) x 8.25 (Btu/gal-F) x                                                                                      Measured Volume (gal) x 70                                                                                      (degrees F).                                                                                     C. For oil-fired products,                                                                                      apply the following in                                                                                      conducting the thermal                                                                                      efficiency and standby                                                                                      loss tests:                                                                                     (1) Venting                                                                                      Requirements_Connect a                                                                                      vertical length of flue                                                                                      pipe to the flue gas                                                                                      outlet of sufficient                                                                                      height so as to meet the                                                                                      minimum draft specified by                                                                                      the manufacturer.Oil-fired Storage and Instantaneous  Thermal Efficiency....  ANSI Z21.10.3-1998,     (2) Oil Supply_Adjust the Water Heaters and Hot Water Supply                           § 2.9**.           burner rate so that: (a) Boilers*.                                                                            The hourly Btu input rate                                                                                      lies within ±2                                                                                      percent of the                                                                                      manufacturer's specified                                                                                      input rate, (b) the CO2                                                                                      reading shows the value                                                                                      specified by the                                                                                      manufacturer, (c) smoke in                                                                                      the flue does not exceed                                                                                      No. 1 smoke as measured by                                                                                      the procedure in ASTM-D-                                                                                      2156-80, and (d) fuel pump                                                                                      pressure lies within                                                                                      ±10 percent of                                                                                      manufacturer's                                                                                      specifications.                                     Standby Loss..........  ANSI Z21.10.3-1998,     D. For electric products,                                                              § 2.10**.          apply the following in                                                                                      conducting the standby                                                                                      loss test:                                                                                     (1) Assume that the thermal                                                                                      efficiency (Et) of                                                                                      electric water heaters                                                                                      with immersed heating                                                                                      elements is 98 percent.                                                                                     (2) Maintain the electrical                                                                                      supply voltage to within                                                                                      ±5 percent of the                                                                                      center of the voltage                                                                                      range specified on the                                                                                      water heater nameplate.Electric Storage and Instantaneous   Standby Loss..........  ANSI Z21.10.3-1998,     (3) If the set up includes Water Heaters.                                               § 2.10**.          multiple adjustable                                                                                      thermostats, set the                                                                                      highest one first to yield                                                                                      a maximum water                                                                                      temperature in the                                                                                      specified range as                                                                                      measured by the topmost                                                                                      tank thermocouple. Then                                                                                      set the lower                                                                                      thermostat(s) to yield a                                                                                      maximum mean tank                                                                                      temperature within the                                                                                      specified range.----------------------------------------------------------------------------------------------------------------*As to hot water supply boilers with a capacity of less than 10 gallons, these test methods become mandatory on  October 21, 2005. Prior to that time, you may use for these products either (1) these test methods if you rate  the product for thermal efficiency, or (2) the test methods in Subpart E if you rate the product for  combustion efficiency as a commercial packaged boiler.**Incorporated by reference, see § 431.105.