§ 18.24   Electrical clearances.

Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall be as follows:

             Minimum Clearances Between Uninsulated Surfaces------------------------------------------------------------------------                                                    Clearances (inches)                                                 -----------------------                                                               Phase-to-          Phase-to-Phase Voltage (rms)             Phase-to-   Ground or                                                     Phase      Control                                                                Circuit------------------------------------------------------------------------0 to 250........................................        0.25        0.25251 to 600......................................        0.28        0.25601 to 1000.....................................        0.61        0.251001 to 2400....................................        1.4         0.62401 to 4160....................................        3.0         1.4------------------------------------------------------------------------

[57 FR 61209, Dec. 23, 1992]