30 C.F.R. § 250.908   What are the minimum structural fatigue design requirements?


Title 30 - Mineral Resources


Title 30: Mineral Resources
PART 250—OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF
Subpart I—Platforms and Structures
Platform Approval Program

Browse Previous

§ 250.908   What are the minimum structural fatigue design requirements?

(a) API RP 2A-WSD, Recommended Practice for Planning, Designing and Constructing Fixed Offshore Platforms (incorporated by reference as specified in 30 CFR 250.198), requires that the design fatigue life of each joint and member be twice the intended service life of the structure. When designing your platform, the following table provides minimum fatigue life safety factors for critical structural members and joints.

 ------------------------------------------------------------------------              If . . .                            Then . . .------------------------------------------------------------------------(1) There is sufficient structural   The results of the analysis must redundancy to prevent catastrophic   indicate a maximum calculated life failure of the platform or           of twice the design life of the structure under consideration.       platform.(2) There is not sufficient          The results of a fatigue analysis structural redundancy to prevent     must indicate a minimum calculated catastrophic failure of the          life or three times the design platform or structure.               life of the platform.(3) The desirable degree of          The results of a fatigue analysis redundancy is significantly          must indicate a minimum calculated reduced as a result of fatigue       life of three times the design damage.                              life of the platform.------------------------------------------------------------------------

(b) The documents incorporated by reference in §250.901 may require larger safety factors than indicated in paragraph (a) of this section for some key components. When the documents incorporated by reference require a larger safety factor than the chart in paragraph (a) of this section, the requirements of the incorporated document will prevail.

Browse Previous






















chanrobles.com