42 C.F.R. § 84.122   Breathing resistance test; minimum requirements.


Title 42 - Public Health


Title 42: Public Health
PART 84—APPROVAL OF RESPIRATORY PROTECTIVE DEVICES
Subpart I—Gas Masks

Browse Previous |  Browse Next

§ 84.122   Breathing resistance test; minimum requirements.

(a) Resistance to airflow will be measured in the facepiece or mouthpiece of a gas mask mounted on a breathing machine both before and after each test conducted in accordance with §§84.124, 84.125, and 84.126, with air flowing at a continuous rate of 85 liters per minute.

(b) The maximum allowable resistance requirements for gas masks are as follows:

                           Maximum Resistance                        [mm. water-column height]------------------------------------------------------------------------                                          Inhalation         Type of gas mask         --------------------------  Exhalation                                     Initial     Final \1\------------------------------------------------------------------------Front-mounted or back-mounted               60           75           20 (without particulate filter)....Front-mounted or back-mounted               70           85           20 (with approved particulate filter).........................Chin-style (without particulate             40           55           20 filter).........................Chin-style (with approved                   65           80           20 particulate filter).............Escape (without particulate                 60           75           20 filter).........................Escape (with approved particulate           70           85           20 filter).........................------------------------------------------------------------------------\1\ Measured at end of the service life specified in Tables 5, 6, and 7  of this subpart.

Browse Previous |  Browse Next

chanrobles.com