42 C.F.R. Tables to Subpart I of Part 84


Title 42 - Public Health


Title 42: Public Health
PART 84—APPROVAL OF RESPIRATORY PROTECTIVE DEVICES
Subpart I—Gas Masks


Tables to Subpart I of Part 84
                           Table 5_Canister Bench Tests and Requirements for Front-Mounted and Back-Mounted Gas Mask Canisters                                                               [42 CFR part 84, subpart I]--------------------------------------------------------------------------------------------------------------------------------------------------------                                                                                      Test atmosphere                                                                   ----------------------------------------------------              Maximum    Minimum                                                                                                             Flow rate  Number of   allowable   service              Canister type                    Test condition                                 Concentration   (liters     tests    penetratin     life                                                                          Gas or vapor          (parts per      per                (parts per  (minutes)                                                                                                 million)     minute)               million)      \1\--------------------------------------------------------------------------------------------------------------------------------------------------------Acid gas................................  As received               SO2                             20,000          64          3           5         12                                          Equilibrated              Cl2                             20,000          64          3           5         12                                          ........................  SO2                             20,000          32          4           5         12                                          ........................  Cl2                             20,000          32          4           5         12Organic vapor...........................  As received               CCl4                            20,000          64          3           5         12                                          Equilibrated              CCl4                            20,000          32          4           5         12Ammonia.................................  As received               NH3                             30,000          64          3          50         12                                          Equilibrated              NH3                             30,000          32          4          50         12Carbon monoxide.........................  As received               CO                              20,000      \4\ 64          2       (\3\)         60                                          Equilibrated              CO                               5,000      \2\ 32          3       (\3\)         60                                          ........................  CO                               3,000      \2\ 32          3       (\3\)         60Combination of 2 or 3 of above types \5\Combination of all above types \6\--------------------------------------------------------------------------------------------------------------------------------------------------------\1\ Minimum life will be determined at the indicated penetration.\2\ Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C.\3\ Maximum allowable CO penetration will be 385 cm \3\ during the minimum life. The penetration shall not exceed 500 p/m during this time.\4\ Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C-  0 °C.\5\ Test conditions and requirements will be applicable as shown in this table.\6\ Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and  ammonia will be 6 min instead of 12 min.
                                     Table 6_Canister Bench Tests and Requirements for Chin-Style Gas Mask Canisters                                                               [42 CFR part 84, subpart I]--------------------------------------------------------------------------------------------------------------------------------------------------------                                                                                      Test atmosphere                                                                     -------------------------------------------------              Maximum     Minimum                                                                                                            Flow rate  Number of   allowable    service            Canister type                      Test condition                                Concentration   (liters     tests    penetration     life                                                                           Gas or vapor        (parts per      per                 (parts per  (minutes)                                                                                                million)     minute)                million)      \1\--------------------------------------------------------------------------------------------------------------------------------------------------------Acid gas.............................  As received Equilibrated       SO2                          50,000          64          3           5          12                                       .............................  Cl2                           5,000          64          3           5          12                                       .............................  SO2                           5,000          32          4           5          12                                       .............................  Cl2                           5,000          32          4           5          12Organic vapor........................  As received Equilibrated       CCl4                          5,000          64          3           5          12                                       .............................  CCl4                          5,000          32          4           5          12Ammonia..............................  As received Equilibrated       NH3                           5,000          64          3          50          12                                       As received Equilibrated       NH3                           5,000          32          4          50          12Carbon monoxide......................  As received                    CO                           20,000      \2\ 64          2       (\3\)          60                                       .............................  CO                            5,000      \4\ 32          3       (\3\)          60                                       .............................  CO                            3,000      \2\ 32          3       (\3\)          60Combination of 2 or 3 of above types \5\Combination of all above types \6\--------------------------------------------------------------------------------------------------------------------------------------------------------\1\ Minimum life will be determined at the indicated penetration.\2\ Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 ° C.\3\ Maximum allowable CO penetration will be 385 cm \3\ during the minimum life. The penetration shall not exceed 500 p/m during this time.\4\ Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C-  0° C.\5\ Test conditions and requirements will be applicable as shown in this table.\6\ Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and  ammonia will be 6 min instead of 12 min.
                                       Table 7_Canister Bench Tests and Requirements for Escape Gas Mask Canisters                                                               [42 CFR part 84, subpart I]--------------------------------------------------------------------------------------------------------------------------------------------------------                                                                                      Test atmosphere                                                                     -------------------------------------------------              Maximum     Minimum                                                                                                            Flow rate  Number of   allowable    service            Canister type                      Test condition                                Concentration   (liters     tests    penetration     life                                                                           Gas or vapor        (parts per      per                 (parts per  (minutes)                                                                                                million)     minute)                million)      \1\--------------------------------------------------------------------------------------------------------------------------------------------------------Acid gas.............................  As received..................  SO2                           5,000          64          3           5          12                                       Equilibrated.................  Cl2                           5,000          64          3           5          12                                                                      SO2                           5,000          32          4           5          12                                                                      Cl2                           5,000          32          4           5          12Organic vapor........................  As received..................  CCl4                          5,000          64          3           5          12                                       Equilibrated.................  CCl4                          5,000          32          4           5          12Ammonia..............................  As received..................  NH3                           5,000          64          3          50          12                                       Equilibrated.................  NH3                           5,000          32          4          50          12Carbon monoxide......................  As received..................  CO                           10,000      \2\ 32          2       (\3\)      \4\ 60                                                                      CO                            5,000      \5\ 32          3       (\3\)          60                                                                      CO                            3,000      \2\ 32          3       (\3\)          60--------------------------------------------------------------------------------------------------------------------------------------------------------\1\ Minimum life will be determined at the indicated penetration.\2\ Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere will be 25 ±2.5 °C.\3\ Maximum allowable CO penetration will be 385 cm \3\ during the minimum life. The penetration shall not exceed 500 p/m during this time.\4\ If effluent temperature exceeds 100° C during this test, the escape gas mask shall be equipped with an effective heat exchanger.\5\ Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C-  0 °C.





chanrobles.com