46 C.F.R. § 32.56-22 Openings in and insulation of boundaries: Other spaces—T/ALL.
Title 46 - Shipping
If openings are fitted into the following exterior boundaries of any space other than an accommodation, service, or control space, the interior of the space must be insulated to “A-60” Class and the space must not provide access to any accommodation, service, or control space: (a) The exterior boundaries that face the cargo area. (b) The portion of the exterior boundaries within 3 meters (10 feet) or the length of the vessel divided by 25, whichever is greater, except that the distance need not exceed 5 meters (16.4 feet), of these boundaries.
Title 46: Shipping
PART 32—SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS
Subpart 32.56—Structural Fire Protection for Tank Ships With a Keel Laying Date On or After January 1, 1975
§ 32.56-22 Openings in and insulation of boundaries: Other spaces—T/ALL.