46 C.F.R. PART 34--FIREFIGHTING EQUIPMENT


TITLE 46--Shipping

CHAPTER I--COAST GUARD, DEPARTMENT OF HOMELAND SECURITY

SUBCHAPTER D--TANK VESSELS

PART 34--FIREFIGHTING EQUIPMENT

rule

Subpart 34.01--GENERAL

�34.01-1
Applicability--TB/ALL.
�34.01-5
Equipment installed but not required--TB/ALL.
�34.01-10
Protection for unusual arrangements or special products--TB/ALL.
�34.01-15
Incorporation by reference.
rule

Subpart 34.05--FIREFIGHTING EQUIPMENT, WHERE REQUIRED

�34.05-1
Fire main system--T/ALL.
�34.05-5
Fire-extinguishing systems--T/ALL.
�34.05-10
Portable and semiportable extinguishers--TB/ALL.
�34.05-20
Fire axes--T/ALL.
rule

Subpart 34.10--FIRE MAIN SYSTEM, DETAILS

�34.10-1
Application--TB/ALL.
�34.10-5
Fire pumps--T/ALL.
�34.10-10
Fire station hydrants, hose and nozzles--T/ALL.
�34.10-15
Piping--T/ALL.
�34.10-90
Installations contracted for prior to May 26, 1965--T/ALL.
rule

Subpart 34.13--STEAM SMOTHERING SYSTEMS

�34.13-1
Application--T/ALL.
rule

Subpart 34.15--CARBON DIOXIDE EXTINGUISHING SYSTEMS, DETAILS

�34.15-1
Application--T/ALL.
�34.15-5
Quantity, pipe sizes, and discharge rates--T/ALL.
�34.15-10
Controls--T/ALL.
�34.15-15
Piping--T/ALL.
�34.15-20
Carbon dioxide storage--T/ALL.
�34.15-25
Discharge outlets--T/ALL.
�34.15-30
Alarms--T/ALL.
�34.15-35
Enclosure openings--T/ALL.
�34.15-40
Pressure relief--T/ALL.
�34.15-90
Installations contracted for prior to January 1, 1962--T/ALL.
rule

Subpart 34.17--FIXED FOAM EXTINGUISHING SYSTEMS, DETAILS

�34.17-1
Application--T/ALL.
�34.17-5
Quantity of foam required--T/ALL.
�34.17-10
Controls--T/ALL.
�34.17-15
Piping--T/ALL.
�34.17-20
Discharge outlets--T/ALL.
�34.17-25
Additional protection required--T/ALL.
�34.17-90
Installations contracted for prior to January 1, 1962--T/ALL.
rule

Subpart 34.20--DECK FOAM SYSTEM, DETAILS

�34.20-1
Application--T/ALL.
�34.20-3
Cargo area definition--T/ALL.
�34.20-5
Quantity of foam required--T/ALL.
�34.20-10
Controls--T/ALL.
�34.20-15
Piping--T/ALL.
�34.20-20
Discharge outlets--T/ALL.
�34.20-25
Foam monitor capacity--T/ALL.
�34.20-90
Installations contracted for prior to January 1, 1970--T/ALL.
rule

Subpart 34.25--WATER SPRAY EXTINGUISHING SYSTEMS, DETAILS

�34.25-1
Application--T/ALL.
�34.25-5
Capacity and arrangement--T/ALL.
�34.25-10
Controls--T/ALL.
�34.25-15
Piping--T/ALL.
�34.25-20
Spray nozzles--T/ALL.
�34.25-90
Installations contracted for prior to January 1, 1964--T/ALL.
rule

Subpart 34.30--AUTOMATIC SPRINKLER SYSTEMS, DETAILS

�34.30-1
Application--TB/ALL.
rule

Subpart 34.50--PORTABLE AND SEMIPORTABLE EXTINGUISHERS

�34.50-1
Application--TB/ALL.
�34.50-5
Classification--TB/ALL.
�34.50-10
Location--TB/ALL.
�34.50-15
Spare charges--TB/ALL.
�34.50-20
Semiportable fire extinguishers--TB/ALL
�34.50-90
Vessels contracted for prior to January 1, 1962--TB/ALL.
rule

Subpart 34.60--FIRE AXES

�34.60-1
Application--T/ALL.
�34.60-5
Number required--T/ALL.
�34.60-10
Location--T/ALL.
rule



chanrobles.com


ChanRobles Legal Resources:

ChanRobles On-Line Bar Review

ChanRobles Internet Bar Review : www.chanroblesbar.com

ChanRobles MCLE On-line

ChanRobles Lawnet Inc. - ChanRobles MCLE On-line : www.chanroblesmcleonline.com