49 C.F.R. § 192.115   Temperature derating factor (T) for steel pipe.


Title 49 - Transportation


Title 49: Transportation
PART 192—TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS
Subpart C—Pipe Design

Browse Previous |  Browse Next

§ 192.115   Temperature derating factor (T) for steel pipe.

The temperature derating factor to be used in the design formula in §192.105 is determined as follows:

 ------------------------------------------------------------------------                                                             Temperature      Gas temperature in degrees Fahrenheit (Celsius)          derating                                                              factor (T)------------------------------------------------------------------------250 °F (121 °C) or less............................        1.000300 °F (149 °C)....................................        0.967350 °F (177 °C)....................................        0.933400 °F (204 °C)....................................        0.900450 °F (232 °C)....................................        0.867------------------------------------------------------------------------

For intermediate gas temperatures, the derating factor is determined by interpolation.

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192–85, 63 FR 37502, July 13, 1998]

Browse Previous |  Browse Next