49 C.F.R. § 230.80 Cabs.
Title 49 - Transportation
(a) General provisions. Cabs shall be securely attached or braced and maintained in a safe and suitable condition for service. Cab windows of steam locomotives shall provide an undistorted view of the track and signals for the crew from their normal position in the cab. Cab floors shall be kept free of tripping or slipping hazards. The cab climate shall be maintained to provide an environment that does not unreasonably interfere with the engine crew's performance of their duties under ordinary conditions of service. (b) Steam pipes. Steam pipes shall not be fastened to the cab. New construction or renewals made of iron or steel pipe greater than (c) Oil-burning steam locomotives. If the cab is enclosed, oil burning steam locomotives that take air for combustion through the fire-door opening shall have a suitable conduit extending from the fire-door to the outside of the cab.
Title 49: Transportation
PART 230—STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS
Subpart C—Steam Locomotives and Tenders
Cabs, Warning Signals, Sanders and Lights
§ 230.80 Cabs.