46 C.F.R. § 154.438 Design vapor pressure.
Title 46 - Shipping
(a) If the surface of an independent tank type A are mostly flat surfaces,the Po must not exceed 69 kPa gauge (10 psig). (b) If the surfaces of an independent tank type A are formed by bodies of revolution, the design calculation of the Po must be specially approved by the Commandant (G-MSO). [CGD 74–289, 44 FR 26009, May 3, 1979, as amended by CGD 82–063b, 48 FR 4782, Feb. 3, 1983]
Title 46: Shipping
PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES
Subpart C—Design, Construction and Equipment
Independent Tank Type A
§ 154.438 Design vapor pressure.