46 C.F.R. § 154.1160 Monitor coverage of system.
Title 46 - Shipping
The coverage of each dry chemical system monitor under §154.1150 must not exceed: (a) 10 m (32.8 ft.) at 10 kg/sec (22 lb/sec); (b) 30 m (98.4 ft.) at 25 kg/sec (55 lb/sec); (c) 40 m (131.2 ft.) at 45 kg/sec (99 lb/sec); (d) An interpolation between 10 m (32.8 ft.) at 10 kg/sec (22 lb/sec) and 30 m (98.4 ft.) at 25 kg/sec (55 lb/sec); or (e) An interpolation between 30 m (98.4 ft.) at 25 kg/sec (55 lb/sec) and 40 m (131.2 ft.) at 45 kg/sec (99 lb/sec).
Title 46: Shipping
PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES
Subpart C—Design, Construction and Equipment
Firefighting System: Dry Chemical
§ 154.1160 Monitor coverage of system.